CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: sick hp 5421A Digital Processor
Hello Dave, just in case my e-mail reply to your kind offer ended in your spam folder: you got mail ;-) Kind regards Chris
By
ChrisBeee
·
#103575
·
|
HP 5347A with 8482A Power Sensor?
Hello group. Wondering if anyone has tried using the 8482A power sensor with the 5347A. It is the only sensor I have. Power ranges are the same but not the frequency range so clearly cannot measure
By
Mark Bielman
·
#103574
·
|
WTB HP 8660C Module Extension Cables 11672
I wish to buy the Service Kit p/n 11672A, or the two extender cables, p/n 11672-60001 and 11672-60002 for the 8660x signal generator series. Please contact me off list if you have something for sale.
By
Bob Koller <testtech@...>
·
#103573
·
|
Re: HP3336b
To quote Wikipedia, as just one example.... "An RCA connector, sometimes called a phono connector or (in other languages) Cinch connector, is a type of electrical connector commonly used to carry
By
Nigel
·
#103572
·
|
Re: A dirty way to get more frequency resolution out of a signal generator
This will probably work but you would need a counter to verify the output signal is what you are expecting. There is no guaranty that a low resolution generator will be able to hold steady on digits
By
victor.silva
·
#103571
·
|
Re: [WANTED] HP 85700A 32kB RAM card
Hi Steve, On the screen issue, try the display centering adjustments on the second page of the CAL menu. If that doesn't help. over-scan and centering problems can also be caused by the wrong sync.?
By
Mark Litwack
·
#103570
·
|
Re: HP3325 - no output, but sync works
Simple check is to take the cover off, locate the attenuator board and find the input cable. Put a scope on that and it should have a signal ¨C this would prove the rest of the generator is
By
nigel adams
·
#103569
·
|
Re: HP3325 - no output, but sync works
Odds are the attenuators is shot. If it has the flat black aeromat relays you won¡¯t hear them even if the work. They are latching type so checking the drive signal will only give you a plus. You
By
Stephen Hanselman
·
#103568
·
|
Re: LO port on HP 8591A
Thanks, your comment made me laugh. Glad to hear its not just about saving $20 anymore and we now actually have another brand/series of SA that it can be used for.
By
Marcus Bannerman
·
#103567
·
|
Re: Hi all..have a question on a source for micro-grabber clips (smd size)
Something like HP 5090-4356? Plenty around on ebay at a $ or so each. wrote:
By
Orin Eman
·
#103566
·
|
Re: Hi all..have a question on a source for micro-grabber clips (smd size)
I don't know if something like this is what you're talking about, but I thought I'd offer it on the chance that it was what you're looking for.
By
G Hopper, KB7WSD
·
#103565
·
|
Re: Finding feet for older HP gear
Hi Sean you are asking for components but you forgot to give your location Paul located England _____ From: [email protected] [mailto:[email protected]] On
By
Paul Bicknell
·
#103564
·
|
Re: Hi all..have a question on a source for micro-grabber clips (smd size)
Are you able to put up an image of what you are looking for, might help folk understand more clearly what you are after. Regards Nigel ________________________________ Sent: 02 March 2020 04:07:19 To:
By
nigel adams
·
#103563
·
|
Re: HP3325 - no output, but sync works
Joe and Szabolcs: thanks for the ideas! I have not yet opened the box (after years...). Since this unit came from my employer, who has a metrology, and calibration group, I¡®m betting on the bad
By
Randy Newman
·
#103562
·
|
Hi all..have a question on a source for micro-grabber clips (smd size)
Hi all: I am in the process of troubleshooting a Tek AM503 current probe amplifier and am looking for the small SMD sized type of grabber clips. I have some of the larger Pomona types with the
By
Randy Newman
·
#103561
·
|
Finding feet for older HP gear
Hi all, I have a number of examples of the older style case HP gear (8640B, 8405A, and now a 3440A) that all lost their feet at some point before I got them. I know these feet are rather scarce, but I
By
Sean Turner
·
#103560
·
|
Re: [WANTED] HP 85700A 32kB RAM card
The logical step in any situation is to replace a failed component.? But when one relies 100% upon a mission critical part, without knowing that it failed, they can be subtly surprised if it had
By
Greg Muir
·
#103559
·
|
Re: Fuses for 5350B input 2 [lower frequency input]
Thankyou Askild, and Greg. I have an inquiry in to one of the suppliers on eBay. Shipping showed as about $350 - I think this is a little too high, and might be an error ;). I have a 5350B on its way
By
donald collie
·
#103558
·
|
Re: A dirty way to get more frequency resolution out of a signal generator
I should point out I have not attempted this as I had no reason to, why I am sharing this is that it appears to be an unusual exploit should you desire a more fine frequency control though not without
By
DW
·
#103557
·
|
Re: [WANTED] HP 85700A 32kB RAM card
... Relying on super caps is not 100%.? I have found bad ones. ... It's better to be safe than always assume goodness. I never assume goodness, hence my statement to always do a backup. A backup
By
Mark Litwack
·
#103556
·
|