Re: NVRAM 28-Pin Encapsulated Package DS1230Y and 6811B
Maybe not!! some of these Dallas devices have a battery in the socket to maintain the contents. It may not be one of those but do check before removing anything. The "socket" may actually be a header and the whole thing unplugged and read in a programmer as if it was an EPROM. I last came across these in the 1990s using prototyping/development kits. Others are rather "fat" 28-pin (0.6in.) IC shapes and have an internal battery I think.
Alan G3NYK |
NVRAM 28-Pin Encapsulated Package DS1230Y and 6811B
开云体育Hello, I am doing maintenance on my instruments in my lab at the moment and I have a 6811B which poses a problem for me: the calibration constants are stored in a NVRAM whose date code is 1998, the device works well but no doubt it would be advisable to change this circuit without losing the data before the problems occur. We are talking here about the Dallas DS1230Y (28-Pin Encapsulated Package), the integrated circuit is mounted on a socket. ? I have a programmer Xeltek EPROM super pro Model 3000U available, and has in its library the DS1230Y. I am not familiar with this kind of circuit, but from my understanding, I would have to carefully remove the DS1230Y from its socket and make a copy on my EPROM program. ? Is it a good idea to try to do this, or there is a better solution? Normally the DS1230Y should keep its data since there is an integrated battery. ? Yves |
Re: Understanding the 8753ES frequency loop
toggle quoted message
Show quoted text
On Mar 21, 2019, at 2:29 PM, pianovt via Groups.Io <pianovt@...> wrote:
|
Re: Understanding the 8753ES frequency loop
Hi Peter,
You did a YTO swap, but it didn’t help, right? I guess, unless you know that your spare YTO is good, the result may not be conclusive. Here is some additional YTO information for you: The main coil sensitivity is 23 mA/GHz? (+/- 1 mA/GHz). At lower frequencies (3.8 to 5+ GHz), the YTO is pretty linear. If you draw a straight line between 3.8 and 5.5 GHz, the deviation should be less than 3MHz, if that. The FM coil sensitivity is around 230kHz/mA. Maximum allowed FM coil current is 150mA. Vladan |
Re: Understanding the 8753ES frequency loop
Pete Manfre
Me too… going on 4 weeks and just starting to get better.? ?Worst cold I have?ever had.? Pete On Thu, Mar 21, 2019, 2:00 PM Peter Gottlieb <hpnpilot@...> wrote:
|
Re: HP 8664A signal generator repairability
Thanks for all the hints on power meters! Duly noted.
As for the 8664, it passes all self tests. I also re-ran self cal now that the frequency reference is good and warm and everything seems to be working absolutely great. I negotiated a bit of refund back from the seller for the pain and suffering, and I have an order of rack handles on the way 2 4U sets (so I can put some handles on my 8569B microwave SA as well), and some extra 3U handles. Sean |
Re: Understanding the 8753ES frequency loop
开云体育Thank you.?I’m still recovering from a real nasty flu/cold so everything is going really slowly here.? I’m hoping that what I find is helpful to others as I have heard from another group member of a nearly identical problem. I’d like to post sufficient information such that anyone else running into this will have specific accurate numbers to compare against and hopefully to lead to more repaired units.? Peter On Mar 21, 2019, at 1:53 PM, Pete Manfre <pmanfre@...> wrote:
|
Re: Understanding the 8753ES frequency loop
Pete Manfre
New board should be to you tomorrow.? Pete wa2odo On Thu, Mar 21, 2019, 1:32 PM Peter Gottlieb <hpnpilot@...> wrote:
|
Re: Understanding the 8753ES frequency loop
开云体育Thank you. All this helps me piece together how the setup works. Right now I am collecting data and once it starts forming a coherent picture I will post it.?The firmware plays a big part in this as well. For example, after default pretune values are set, test 48 creates individualized pretune values for that specific instrument. There is only so far that can compensate, though, and that’s apparently what I’m running into. ?What I don’t yet know is whether the problem is on that board or if the YIG oscillator has drifted out of spec. It would be helpful to know just how far that firmware can compensate. I do see that my analog bus voltages are spot on, and seeing how your pretune voltage waveform is lower than mine, I still suspect a problem on my phase lock board. I have verified that the voltage to current converter is operating properly, and since the measurement resistor is verified well within its 1% tolerance, that the current through the YTO main coil should thus be within design tolerance as compared to the 1V/GHz signal. Thus any inability to be lower in voltage would have to be in the DAC, reference, voltage shift area that feeds the V/I converter. If however the replacement phase lock board has the exact same behavior I would have to look again at the YIG oscillator.? Peter On Mar 20, 2019, at 11:17 PM, pianovt via Groups.Io <pianovt@...> wrote:
|
Re: HP 3563A (3562A) A9 FFT
morestainless
The 2nd FFT board arrived, sourced less than 1hr from here, and it is a good board.? All self tests passed.? The 3563A is working!??
toggle quoted message
Show quoted text
|
Re: HP 8664A signal generator repairability
开云体育Seconded,? I have gotten bit by the 2nd or 3rd harmonic even on a good meter.? Bird is considered a 5 or 10% meter at best great for tuning bad for accuracy ? Regards, ? Stephen Hanselman Datagate Systems, LLC 3107 North Deer Run Road #24 Carson City, Nevada, 89701 (775) 882-5117 office (775) 720-6020 mobile a Service Disabled, Veteran Owned Small Business DISCLAIMER: This e-mail and any attachments are intended only for use by the addressee(s) named herein and may contain legally privileged and/or proprietary information. If you are not the intended recipient, any dissemination, distribution or copying of this e-mail and any attachments is strictly prohibited. If you have received this e-mail in error, please immediately notify me and permanently delete the original and all copies and printouts of this e-mail and any attachments. ? ? ? From: [email protected] <[email protected]> On Behalf Of alwyn.seeds1
Sent: Thursday, March 21, 2019 3:35 AM To: [email protected] Subject: Re: [HP-Agilent-Keysight-equipment] HP 8664A signal generator repairability ? Dear All, ? "From:?Bob Albert ? For a decent power meter you do NOT want a Bird.? They are pretty sloppy." ? Sorry for using the vague term “decent power meter”. I meant something like an HP 435/436 with an 8481A measurement head. ? The Bird instruments are intended for measuring rather larger RF powers and, as Bob says, do not offer the accuracy required for testing a signal generator. ? While writing, a tip to avoid the mistake I once made. Power meters are, of course, broadband. Therefore if the signal to be measured has significant harmonic content an error in measuring the fundamental power will result. Forgetting about this, I was puzzling why the Cal. outputs of my 8560 series and 8590 series spectrum analysers measured differently. Then I realised that the 8590 Cal. source has strong harmonic output, whereas the 8560 series source does not. ? Similarly, some signal generators that use frequency doublers produce strong half-frequency outputs which would cause an error when checking output power on the highest frequency range with a power meter. ? Regards, ? Alwyn ? _____________________________________________________ ? Alwyn Seeds, Director _____________________________________________________ ? |
Re: Signal Generator Comparison Chart ?
I live in Ontario Canada and get heavy items shipped to the UPS Store in Ogdensburg NY, sometimes saving as much as $400 shipping! They charge $5 per package for 10 or 15 days, check. It used to be a week.?? It means 3 hours drive each way but my wife and I make a trip of it. PeterB On Wed, Mar 20, 2019 at 10:56 PM amirb <amir.borji@...> wrote: I have also been in the market for a 26GHz SG for a while with no luck. Although I have to say the biggest issue for me |
Re: 8970b
kevin kearns
Thanks Tom, I will try it! Kevin
toggle quoted message
Show quoted text
----- Original Message -----
From: "Tom Holmes" <tholmes@...> To: <[email protected]> Sent: Thursday, March 21, 2019 1:18 AM Subject: Re: [HP-Agilent-Keysight-equipment] 8970b Use SP 1.3, since you have a more or less fixed IF frequency. Page 3-128 in |
Re: HP 8664A signal generator repairability
开云体育Dear All,"From:?Bob Albert Date: Wed, 20 Mar 2019 17:28:34 PDT? For a decent power meter you do NOT want a Bird.? They are pretty sloppy." Sorry for using the vague term “decent power meter”. I meant something like an HP 435/436 with an 8481A measurement head. The Bird instruments are intended for measuring rather larger RF powers and, as Bob says, do not offer the accuracy required for testing a signal generator. While writing, a tip to avoid the mistake I once made. Power meters are, of course, broadband. Therefore if the signal to be measured has significant harmonic content an error in measuring the fundamental power will result. Forgetting about this, I was puzzling why the Cal. outputs of my 8560 series and 8590 series spectrum analysers measured differently. Then I realised that the 8590 Cal. source has strong harmonic output, whereas the 8560 series source does not. Similarly, some signal generators that use frequency doublers produce strong half-frequency outputs which would cause an error when checking output power on the highest frequency range with a power meter. Regards, Alwyn _____________________________________________________ Alwyn Seeds, Director SynOptika Ltd., 114 Beaufort Street, London, SW3 6BU, England. Tel.: +44 (0) 20 7376 4110 SynOptika Ltd., Registered in England and Wales: No. 04606737 Registered Office: 114 Beaufort Street, London, SW3 6BU, United Kingdom. _____________________________________________________
|
Re: Signal Generator Comparison Chart ?
On Wed, Mar 20, 2019 at 10:06 PM, Tim Tuck wrote:
Next comes Wiltron synthesizers 67xx. The one I have been looking for is 6759B which is 10MH - 26.5GH synthesized with very good specs. very close to 8673B actuallyThey look nice, but I don't know anything about them - I've kept with HP for 99% of my lab because its reliable and I can service them but if there's reasonable documentation, parts etc. for those, I may consider it.
I still haven't figured out exactly if the PM 1038 can handle up to 26GHz and if so... which modules.? Reads there are sensors/detectors that do rate up to 26GHz.? |
Re: Signal Generator Comparison Chart ?
G'Day,
On 21/03/2019 1:56 pm, amirb wrote: I have also been in the market for a 26GHz SG for a while with no luck. Although I have to say the biggest issue for meYep - I hear ya. At least it can be road freight from the US to you, I'm on a bloody big island! with regard to models: I missed out on a 8673G for $800 just recently :( - I do like those units since they can drive the millimeter-wave sources, and ... at some point... I'd be looking to get one or two of those two since I'm slowly working through the SHF bands building transverters and I intend to end up on 122Ghz at some point. I only need something to go from 3Ghz up since I have an ESG4432b to cover from 3Ghz down as well as a couple of other gens for down to a uHz. Yes they are nice ! -? I have a saved search for them too.
I'm in no hurry and they would be a last resort, one of my associates has one and a few plugins and a bunch of external attenuators, but its all too much kit and I only have a little lab that already has too many things in it, so what ever I get something has to leave to make room. They look nice, but I don't know anything about them - I've kept with HP for 99% of my lab because its reliable and I can service them but if there's reasonable documentation, parts etc. for those, I may consider it. Yeah... and that's the thing isn't it. I see no point expending $ on kit if there's no support. Thanks for the pointers, I'll do some research. regards Tim |
Re: 16900A ballpark pricing and info
Glen,
toggle quoted message
Show quoted text
Thanks for the previous two messages. Good progress: The machine boots right into XP without problems. Needed to work around passwords on the unit, but that was easy enough using chntpw. Self-tests pass on all modules, except for those that I believe require external hardware or configuration to pass. The fitted 80GB IDE drive has only about 10GB in use. It's amazing what used to get us by. I ordered a SIL3114-based PCI-SATA card -- the best I can tell this should be supported natively. The USB ports are only USB 1.1 on the unit, which rules out using flash drives for anything "serious." I hope that gigabit ethernet will be faster! Also ordered a cheap SSD which should perform at least better and more reliably than an old rusty spinner. Keysight support has been great, and provided both BIOS update disc which I caught wind of, and a factory reset OS disk image. I haven't tried these yet, but will soon to at least ensure their integrity. There are MacroVision lmtools .lic files in the Program Files directory. I think they get "applied" to the modules which I believe writes an EEPROM or some NVRAM on the module itself. According to support, no files need copied/persisted in order to maintain the options....They call the .lic files "Entitlement Certificates" which get emailed. They are small ~152 byte files. Thanks, Keith On 3/19/2019 3:11 PM, Glen Slick wrote:
oops, faulty memory. The 16900A, 16902A, and 16903A drives are regularI still have to dig into this. Are the HDDs regular 3.5" SATA's? I mightThe 16900A, 16902A, and 16903A drives are regular 3.5" SATA drives. |
Re: HP5335A fan replacement
Dan Nessett
On Tue, Mar 19, 2019 at 07:22 PM, Joe / KN5U wrote:
By the way, the original fan was 120 VAC, but repair note changed the fan to 24 VDC. This was precipitated by the power supply relay and socket overheating. The repair note had a description of a circuit mod using a diode and also replacing the fan and socket. I have done a few of these mods and this a fairly simple fix. Let me know if you need a copy of the change.The fan on my HP5335A is 24V, so I guess the modification you mention has already been applied. |
Re: HP5335A fan replacement
Dan Nessett
On Tue, Mar 19, 2019 at 07:17 PM, Joe / KN5U wrote:
Dan,Thanks Joe. I will look for another fan with better airflow characteristics. Of course, I could always go for a Papst fan with better noise characteristics. |