Stellex YIGs
Does anyone has a detailed datasheet of the stellex permanent magnet
YTOs that are commonly offered on ebay ? im especially interested in
the max current the coil can take without frying.
Im in the
By
microwaveengineer1968 <microwaveengineer1968@...>
·
#9127
·
|
Re: DIY: Repair of HP Step Attenuators
Thanks John!
Best
George
hour chasing
By
g47g
·
#9126
·
|
Re: Hp-8443A Tracking Generator Problems
They are very likely Sealectro or MicroDot. If you email me a (small ) pic of
both M and F, off list, I'll see if I can ID them.
If they are gold plated with Teflon insulation between center and
By
J Forster <jfor@...>
·
#9125
·
|
Re: Hp-8443A Tracking Generator Problems
If you can email me photographs, I'll compare them to
what's in my 8443A.
But it doesn't really matter. The only important one
for your present purpose is A6W1, the one from the RF amp to
the
By
Dave Wise
·
#9124
·
|
Re: Hp-8443A Tracking Generator Problems
I did call them GOOFY because that is what they are. They are goofy because
I think the only place in the whole world they were used was the jacks and
plugs for the cables of the connections between
By
David C. Hallam <dhallam@...>
·
#9123
·
|
Re: Hp-8443A Tracking Generator Problems
I didn't call them goofy, David Hallam (the OP) did.
You and I are referring to what's more commonly called
"Hybrid-D" connectors. (From context,
I judge that David Hallam is thinking of the SMB
By
Dave Wise
·
#9122
·
|
Re: Hp-8443A Tracking Generator Problems
Sealectro is a brand. They made SMA, SMB, SMC, and a number of other miniature
coax connectors. They ALSO made a number of proprietary types in addition to the
standards.
As to 'goofy', do you mean
By
J Forster <jfor@...>
·
#9120
·
|
Re: HP-8443A Tracking Generator Problems
I said that two sentences later:
"At narrow
RBW settings, you have to fine-tune the TG to be exactly
on frequency, that's the screwdriver adjustment on the front
panel. Since you don't know that
By
Dave Wise
·
#9121
·
|
Re: HP-8443A Tracking Generator Problems
ONLY, if the TG is actually putting out the same frequency as the SA is
tuned to. I have an AIL 757 and TG. If the tracking control is not tuned
right, the YIG in the SA's front end will be tuned to a
By
J Forster <jfor@...>
·
#9119
·
|
Re: HP-8443A Tracking Generator Problems
Take a look at the Wiltrons. The advantage is that the marker accuracy is independent of the GHz/Volt calibrations. In fact, I have a little home brew unit in a Tek TM-500 PI that does just that...
By
J Forster <jfor@...>
·
#9118
·
|
Re: DIY: Repair of HP Step Attenuators
FWIW, do it over a tray w/ turned up edges. I just spent over an hour chasing
small bits of an assembly because I ignored that precaution.
Best,
-John
g47g wrote:
By
J Forster <jfor@...>
·
#9116
·
|
Re: Hp-8443A Tracking Generator Problems
They did call them by an obsolete name, "selectro" (or was it "sealectro"?).
By
Dave Wise
·
#9117
·
|
Re: Hp-8443A Tracking Generator Problems
usually HP used SMC and SMB on the inside of most instrument, i havent seen anything special in any of the HP Gear
Dan Rae <danrae@...> wrote: David C. Hallam wrote:
David if you
By
lothar baier <microwaveengineer1968@...>
·
#9115
·
|
Re: Hp-8443A Tracking Generator Problems
David C. Hallam wrote:
David if you do look for another one, try to find a later one with LED displays rather than nixie tubes, they are a little bit more reliable.
But they are pretty easy to work
By
Dan Rae
·
#9114
·
|
Hp-8443A Tracking Generator Problems
Thank you to all who replied to my request for help. I now understand more
about the operation of this piece of test gear and also believe the solution
to my problem is more complex than I originally
By
David C. Hallam <dhallam@...>
·
#9113
·
|
Re: DIY: Repair of HP Step Attenuators
Thanks. I'll try to disassemble the unit, then I hope I'll see the
reason of the failure.
<microwaveengineer1968@...> wrote:
cam in place is missing
By
g47g
·
#9111
·
|
Re: HP-8443A Tracking Generator Problems
You don't even have to select zero span. The function and
purpose of a TG is to output, at all times, whatever frequency
the SA is listening to. As the SA scans, so does the TG.
In all scan modes,
By
Dave Wise
·
#9110
·
|
Re: HP-8443A Tracking Generator Problems
I cant be bothered to look at the manual as it it out of reach, but has it
occured that you are assuming that the marker and RF output are
connected......they may not be. Check you actually have a RF
By
Alan Melia
·
#9112
·
|
Re: DIY: Repair of HP Step Attenuators
most likely the cam is worn out or the little ball that locks the cam in place is missing
g47g <g47g@...> wrote: Hi Lothar,
I have a 8495A manual step attenuator, and though it has
By
lothar baier <microwaveengineer1968@...>
·
#9109
·
|
Re: HP-8443A Tracking Generator Problems
yes i think so
John Miles <jmiles@...> wrote: Isn't that what the 86222 sweeper plugin with the marker option does? Those
are pretty common.
-- john, KE5FX
By
lothar baier <microwaveengineer1968@...>
·
#9108
·
|