Re: 54001A Probe & 54100D Oscilloscope manual
Hey Don,
Mine came with four 54002 50 ohm pods. Expensive little things when purchased new ($130)! I took one apart and they have one little 50 Ohm resister to ground; the rest is plastic and the
By
John McClung
·
#48810
·
|
Re: 3457a on the way
Well I got the HP 3457a in today. It was well packaged so the damage the currier tried to do to the box didn't impact anything.
The serial number prefix on the meter starts with 3114A and it's had 34
By
Jeff Machesky
·
#48809
·
|
Re: Fluke Equipment Group??
I have. NOS manual plus NOS 2170A
By
Keith Erickson
·
#48808
·
|
Re: 54001A Probe & 54100D Oscilloscope manual
Thanks for the extra info, hopefully it will all work out.
Don.
By
Jaanette Black
·
#48807
·
|
Re: 54001A Probe & 54100D Oscilloscope manual
I see the font color change didn't make it - everything after "the
signal routes through coaxial cable W24..." should be blue.
SK
By
Steve - Home
·
#48806
·
|
Re: 54001A Probe & 54100D Oscilloscope manual
From the 5371A manual, which uses the same 54002A input pods:
The HP 54002A 50 ohm input pod is electrically a dead short. The input
signal terminates into 50 ohm resistance (A2R42)
ONLY after the
By
Steve - Home
·
#48805
·
|
Re: 54001A Probe & 54100D Oscilloscope manual
Thanks Gary. Do you know if the output from the probe pods to the main
frame is 50 ohms? If the 54002A pods are a direct feed through that
would verify it. I don't have the scope but am awaiting
By
Jaanette Black
·
#48804
·
|
hp 5348A sampler
It appears that the U1 microwave sampler on the A12 microwave module has died.
As far as i can find after many hours of searching on the internet a replacement is not available, does any one know of a
By
Ken goodhew
·
#48803
·
|
Re: HP 8590A fails 2 Calibration Routines Attenuator found to be bad
I have removed the attenuator and tested it and the 10 and 30 db sections are bad. This is a Wavetek 0955-0329 unit and I can not see a way to take it apart to get at the insides. Has anyone done
By
Steve White
·
#48802
·
|
Re: Choosing a quiet replacement fan
One have to consider the specs from the manuals about operational
conditions. Most manuals for HP Test Equipment states under "General
Specificatioms - Environmentals" operating temperature 0 - 40,
By
oz5tg@...
·
#48801
·
|
Re: Best DVM for general purpose work - 3478A or 34401A ?
34401a by a long shot. Its still current in the catalog, is worth over $1000 new, about $700 used, while the 3478a is over 25 years old, 5.5 digit. The 01a series has a lot of the technology in
By
marvgozum <mxg003@...>
·
#48800
·
|
Re: Equipment Rack mount hardware
HI Mike.
HP used a number of different rack mount systems over the years. Can you
provide any info on what specific instruments you want to mount? Or better,
some pictures?
Tom Holmes, N8ZM
Tipp
By
Tom Holmes
·
#48799
·
|
Re: 54001A Probe & 54100D Oscilloscope manual
I got mine from the Agilent website --->
<http://www.home.agilent.com/agilent/techSupport.jspx?searchT=54100D&id=\
54100D:epsg:pro&pageMode=OV&pid=54100D:epsg:pro&cc=US&lc=eng>
By
John McClung
·
#48798
·
|
Re: 54001A Probe & 54100D Oscilloscope manual
Don
Looks like there is a copy of the 54001A manual on KO4BB.com
I could get a slightly better copy but not worth wading through the snow
for to be sure
Cheers
Dave
ArtekManuals
--
Dave
By
Artekmedia <manuals@...>
·
#48797
·
|
Re: 8753D calibration
Dave,
Some of the variants include "pre" and "post" calibration data. That means gathering all the data twice and producing two reports. There are also situations where the uncertainty of a
By
pianovt
·
#48796
·
|
Re: 54001A Probe & 54100D Oscilloscope manual
Don
Let me know if no one comes to your rescue , I think I have the manual
for the 54001A over at the storage unit, not a trivial task to get to
right now as it is -10C and a 1/2 meter of snow to
By
Artekmedia <manuals@...>
·
#48795
·
|
Choosing a quiet replacement fan
I read occasionally that owners of T&M equipment tire of the noise a cooling fan makes and asks for help to determine if/how a quieter replacement can be found. There are many factors at play in such
By
Dave C <davec2468@...>
·
#48793
·
|
Re: 8753D calibration
Dave you just get what you pay for. A bean counter has found a way to charge more from the customer, he probably got a promotion out of it.
Regards
Heinz DH2FA, KM5VT
Von meinem iPhone gesendet
Am
By
Heinz Breuer
·
#48794
·
|
54001A Probe & 54100D Oscilloscope manual
Hello, does anyone have or know of a site where I can get a scam of a manual for the HP 54001A 1GHz probe or the HP54100D scope it's used in. It's particularly the probe info I need but the scope
By
Jaanette Black
·
#48792
·
|
Re: 8753D calibration
No, but I read and reply to posts in random order sometimes.
-John
================
By
J. Forster <jfor@...>
·
#48791
·
|