Re: Accurately measuring 1000pF and 100pF capacitors, to calibrate 4276A?
A General Radio 1422D dual range variable would meet the specification. Needs the calbration chart though. The earlier 722D would be OK if calibrated and used at same temperature.
Not many units neet
By
Robert G8RPI
·
#150406
·
|
Re: 8753C VNA option upgrade
Hello Group,I un-soldered the EEPROM from my HP8753C and went in and modified the necessary bits and I was able to enable options, 002, 006, and 010. I soldered in a IC socket and copied the original
By
G H
·
#150405
·
|
Re: 8753C VNA option upgrade
Here’s the deal: HP (and later Agilent) locked these options behind firmware codes tied to the instrument’s serial number. Back in the day, you’d buy the upgrade, call up HP with your serial,
By
Jinxie
·
#150404
·
|
Re: 8753C VNA option upgrade
Jinxie, do you happen have keyword for unlocking HP 8753E?
Bill? W7AAZ
By
Bill Carver
·
#150403
·
|
Re: 8753C VNA option upgrade
Is this what you need?
Model Number: HP 8753C
Serial Number: 3317UO1709
To add :
002, Harmonic Analysis
010, Time Domain Analysis (Std on 8702D),
enter the keyword: 3 H T 6 U K Z Z Y 2 M M
Note:
By
Jinxie
·
#150402
·
|
HP54502A Oscilloscope fail A/D test and cal
Hi. Glad to join this group.
I have a HP54502A in fairly good condition I want to fix for my workbench. It fails on A/D test (pass D/A and rest) on CHANNEL 2 only. I have no schematics, just the SM,
By
Mr Lurpak's Electronics Rescue
·
#150401
·
|
8753C VNA option upgrade
Good day all,
I hope this message finds you well. Apologies if this is not the correct method of sharing. This topic must have been discussed multiple times as well. If possible, I would like to ask
By
N.keyser@...
·
#150400
·
|
Re: Accurately measuring 1000pF and 100pF capacitors, to calibrate 4276A?
Yep, I'm in Japan, so shipping is a consideration.. I don't have access to any standards here, besides what might pop up on Yahoo Auctions or the like.
By
Jared Cabot
·
#150399
·
|
Re: Accurately measuring 1000pF and 100pF capacitors, to calibrate 4276A?
Yes, besides the variable 722D, there are fixed caps also. Those can weigh just 8 oz and 4 inches long so more shippable to Nippon.
By
John Griessen
·
#150398
·
|
Re: Accurately measuring 1000pF and 100pF capacitors, to calibrate 4276A?
Yes GR used polystyrene for cap standards. Can you borrow some GR gear to use as a reference to put a good
value number on some stable caps to use in your lab?
If not I have an extra GR 722D that
By
John Griessen
·
#150397
·
|
Re: Accurately measuring 1000pF and 100pF capacitors, to calibrate 4276A?
Capacitance standards from General Radio are readily available at places like eBay.
Barry - N4BUQ
By
n4buq
·
#150396
·
|
Accurately measuring 1000pF and 100pF capacitors, to calibrate 4276A?
I've recently been tweaking my 4276A LCZ meter, and I am now at the point of needing 100pF and 1000pF capacitor standards.
All the rest of the things are easy, I can measure resistors etc to
By
Jared Cabot
·
#150395
·
|
Re: HP 3403C True RMS Voltmeter display fault
It happens! I'm okay with that, especially since they were a high chance they were defective anyway. I'll update soon, at least for the supplies and clock.
By
AArnaud
·
#150394
·
|
Re: HP 8670B amplifier - does it ring a bell with anyone?
Am 23.02.2025 um 08:51 schrieb DF6NA Rainer:
By
DF6NA Rainer
·
#150393
·
|
Re: HP 8670B amplifier - does it ring a bell with anyone?
HP 83020A 2-26,5GHz - 30dB gain - 30dBm out
Am 22.02.2025 um 23:54 schrieb David Feldman via groups.io:
By
DF6NA Rainer
·
#150392
·
|
Re: Vintage parts for sale
Thank you for not replying.
Sent: Friday, February 21, 2025 6:05 PM
To: [email protected]
Subject: Re: [HP-Agilent-Keysight-equipment] Vintage parts for sale
In what
By
NICK K. PLUMIDAKIS
·
#150391
·
|
Re: HP 8670B amplifier - does it ring a bell with anyone?
Now look up HP83020A and see if there's any info.
Ed
By
ed breya
·
#150390
·
|
Re: HP 8670B amplifier - does it ring a bell with anyone?
Hi All,
Today (22 Feb) had access to the HP 8670B unit that started this conversation. I've attached three internal photos with close-up of any identifying information I could see.
Did some RF
By
David Feldman
·
#150389
·
|
Re: 8596E Spectrum Analyzer Fault
Not sure about 'autocouple' but the actual range seems to be irrelevant. I've tried several. It's the instant the 'stop' frequency is entered that brings on the fault, whether that be by keypad or
By
Jinxie
·
#150388
·
|
Re: HP141T solid state replacement for the neon reference.
Guys,
I have built 4 more of the BE19400013B neon replacement boards and I am
about to relist them on Ebay.
Mike
From:
By
Michael Bafaro
·
#150387
·
|