Re: Ink ( recipe ) for Hp 2225 Think Jet printer ?
?
Newer products using the Hp 51604 / 51605 type? inkJet ink cartridges !
?
? If anyone thought this Hp ? InkJet technology? went the way of the Dinosaurs,
.... think again.
?
Newer ink chemistry has been devised.
?
? Reiner InkStamp (Ink Stamp)? hand-held? InkJet printers,
? ?
Reiner JetStamp Models 790MP, 792MP, and 990; 798,?
?? &? newer programmable 1025 1025s? ( 96 to 300 dpi )
?
?? capable of printing on porous & nonporous surfaces, Plastic, Metal & Glass !
?
New Ink chemistry Colours:
? Black, Red, Yellow & UV visible
?? Reiner Ink Cartridges ( equivalent to Hp 51604 51605? cartridge types ):
?
?
Black ink: for printing on Plastic & Metal
ner_pdf/REINER_Begleitblatt_
?
Yellow: for printing on Plastic & Metal
?
Aggressive Black: for printing on Plastic Metal & Glass
? Glass:
?
**
?
Also,? older
Canon:
? The Hp 51604 & 51605 Hp InkJet Cartridges were used in a variety of older Canon desktop printing calculators.
Canon BubbleJet? Bubble Jet
BP120,
BP37-DTS,
BP-35
?
? Others ?
?
? ? ? neat !
?
?
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Locked
Re: Wandel & Goltermann DA-30C software..
Good morning, I just stumbled across this looking for the exact same thing.
I have a DA-30C that the RTC battery, Floppy drive and HDD had died. I have it up and running dos again but lost all the W&G specific software.
?
FritsJ, how did you go with re-setting up your DA-30C?
Bernhard Wulf, Would I be able to get a copy of your DA-30 HDD too?
?
?
Cheers,
Allan |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
HP8510 loosing detection above 20GHz
After a long endeavor and with much help of several goups.io members to repair my HP8510 system, I'm now start to see light in the tunnel.
?
With a borrowed HP85102B as IF-Detector the system? works perfectly, up-to the max 26.5GHz
When I use my own HP85102B in the same setup, It works almost OK up to 20GHz (only small glitches) but when the sweep comes exactly above 20GHz the trace is lost (full scale noise). I checked the gain of A9-A11-A13-A14 IF-Mixer's and they seems OK. I also replaced all PNP's in one of modules but without effect. ?
An amplitude or VTO pre-tune issue ????
?
Anyone experience with this strange behavior ?
?
My current setup:
HP85101B HP85102B own, HP85102B (with option HP85103B installed) borrowed HP8515A HP8340A |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Re: Another dead 8753D YTO
Hi Scott,
?
I'll try answer your questions.
Let me first explain the differences between HP8753B & C and newer versions such as D/E/ES/ET.
?
B&C achieves its RF output by mixing a fixed YIG oscillator at 3.8GHz and a YIG Tune Oscillator sweeping between 3.8-6.8GHz. This gives a range of 0-3GHz. The 6GHz option on the B & C versions are done by a frequency doubler.
?
D and newer versions also uses a 3.8GHz YIG oscillator and without the 6 GHz option the YTO sweeps between 3.8-6.8GHz just as the B&C versions. But the D/E/ES/ET 6 GHz does not utilize a frequency double, instead it uses the YTO directly without mixing, i.e. the 6GHz option requires the YTO to be able to sweep between 3-6.8GHz.
?
For more details regarding this I recommend reading the "theory of operation chapters" in the service manuals for respective model.
?
Simon's excellent documentation refers to HP8753C, I have repaired a HP8753D so the YTO requirements differs.
?
1) I have not tried to decode YIG part numbers, some manufacturers have frequency range in the model number, some don't, some does but only on certain model series.
?
a) To repair a B or C version you might get away with a 4-8GHz YTO, if it manages to have enough output power at 3.8GHz. I would certainly take my chances on this. But probably not for a 8753D/E/ES/ET 6GHz replacement which requires enough output power at 3GHz. I guess some 4-8GHz YTO won't even oscillate at 3GHz.
?
My experience is that many YTO works in a similar way with their current consumption and how they need to be controlled. For me the HP economy YTOs are the exception with not requiring negative voltage and only consume less than half the main coil current.
?
b) See above.
c) probably, the Wiltron YTO I used tunes over 2.5GHz-8GHz. The thing is to make the A11 controller give the correct amount of current for the desired frequency.
d) See above
e) No idea
?
I would not buy a original replacement unless it was guaranteed that is has been refurbished. Otherwise it will break sooner than later.
?
Smart people: I relied heavily the work of Simon and had some help from a friend that knows electronics well, I just know enough to know when to ask for help.
?
Best regards
Marcus |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Re: HP instrument sticky case panel surface
When I got my 8510C system, it was a severe case of sticky covers, all of the boxes.
I have tried many recommended detergents with increasing solvent strength which didn't work for me:
household detergent => no
ethanol, isopropanol => no
WD40 => no
Gasoline => no
What finally worked for me was Orange Terpene.
?
The sticky stuff is bleeding out of the plastic. It doesn't automatically happen with age.
I have identical covers that are older and not sticky at all. It must have to do with other stuff in the surrounding atmosphere during storage.
?
Tom
? |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Re: HP 3586 counter reading high
Paul,
I would like to offer another solution for dealing with the drift caused by the crystal controlled oscillators associated with the HP3586B's Product Detector. My method completely eliminates the drift problem and requires only a minor modification to pick off the 15,625 Hz I.F. signal within the 3586B, or any of the 3586 series SLM's. This method only requires a change in how you go about making absurdly accurate frequency measurements. See: Burt, K6OQK Burt I. Weiner Associates Broadcast Technical Services Glendale, California U.S.A. biwa@... K6OQK -- Burt I. Weiner Associates Broadcast Technical Services Glendale, CA 91201 U.S.A. K6OQK |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Re: HP instrument sticky case panel surface
I have successfully removed the sticky surfaces that developed on the top and bottom panels of my old HP equipment by cleaning the panel surface with a solution of simple green. I keep the Simple Green concentrate in my stock of cleaning products so that I can mix various strengths for various tasks the strongest being a 1:1 mix for heavy de-greasing. Even that strong solution did not damage the panel. I followed up with a wipe down with water and, years later, the sticky film has not returned. Of course, the panel was removed from the instrument before cleaning. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Re: HP 3586 counter reading high
Hi Paul,
When you two were working on this mod, did you consider using the clock input on the pic to condition your 10MHz clock reference, and use one of the timer/dividers, to create the clock for your DDS chip? The 8 pin PIC's are kind of limited, you might have to pop up to a 14 pin to get all of the features you need... But you should also be able to lose the transistor clock conditioner circuit... Just a thought. -Chuck Harris On Mon, 11 Nov 2024 17:56:13 -0500 "paulswed via groups.io" <paulswedb@...> wrote: Quite sometime ago maybe 10 years a Ham in Canada did indeed make a |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Re: HP/Agilent/Keysight test equipment. - Digest #5062
开云体育-------- Email original --------
seems possible need option 59 (a 500 mhz oscillator ) and a cable? have a look here good luck Le 12/11/2024 4:16 am, [email protected] a écrit?:
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Re: Can an 8444A be used with an 8569B?
Hi,
toggle quoted message
Show quoted text
Effectively, you need option 059, or a stable external source at 500 MHz. Obviously, the band stops at the limit of the 8444A and not that of the 8569B, max 1500 MHz. As for the 0-10V sweep voltage, this has no effect on the 8444A as it has no input for this signal. This is not a ramp that synchronizes and controls the output frequency of the 8444A, but rather the RF source of the first LO of the 8569B (2060-3550 MHZ) mixed with the sum of the source at 500MHz and the cavity oscillator at 1550 MHz (total 2050 MHz) which will give the output of the tracking generator 8444A, 10MHz to 1500 MHz at the input of the 8569B. In manual scan mode, the 8444A provides a 0-10V voltage at the output of the SCAN OUT connector which will go to the SCAN INPUT connector of the Spectrum (EXT SWEEP for the 8569B), and the 8444A will receive the frequency of the first LO corresponding to the chosen voltage. But I am intrigued by the information about the 8444A and 8566A talking about this, I will try to find it, but if you had the volume number and page it would be faster for me. Yves -----Message d'origine-----
De?: [email protected] <[email protected]> De la part de Don Bitters via groups.io 贰苍惫辞测é?: 12 novembre 2024 00:52 ??: [email protected] Objet?: Re: [HP-Agilent-Keysight-equipment] Can an 8444A be used with an 8569B? It might be possible, but would involve several issues. The 8444A was designed to be used with an 8554A/L, 8555A, and later an 8558A, and later still with and 8568A/B. Does the 8444A have the internal 500MHz oscillator option - options 058 or 059, if not you would have to supply an external 500MHz stable @10dBm or higher. IIRCC, the expected sweep voltage is 0 to +10V, the 8569B does have an external sweep ramp that I believe is also 0 to +10V, but the sweep ramp linearity may not match exactly, in which case you would need to make a sweep offset/gain matching circuit (as described in the 8566A OP/Serv manual, under alignment tools). The track gen sweep range will very much depend on the low band sweep of the 8569B - probably 10MHz - 1.3GHz, or 1.55GHz max. The low band on the 8569B is 10MHz to 1.8GHz in full band sweep - the 8444A cannot go that high, so you cannot use full band sweep, but can set the 8569B to sweep from 10MHz to 1.5GHz in the MHz per div sweep mode. An external sweep trigger is required to sync the sweep, this should come from the 8569B. Don Bitters |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Re: Can an 8444A be used with an 8569B?
It might be possible, but would involve several issues. The 8444A was designed to be used with an 8554A/L, 8555A, and later an 8558A, and later still with and 8568A/B. Does the 8444A have the internal 500MHz oscillator option - options 058 or 059, if not you would have to supply an external 500MHz stable @10dBm or higher. IIRCC, the expected sweep voltage is 0 to +10V, the 8569B does have an external sweep ramp that I believe is also 0 to +10V, but the sweep ramp linearity may not match exactly, in which case you would need to make a sweep offset/gain matching circuit (as described in the 8566A OP/Serv manual, under alignment tools). The track gen sweep range will very much depend on the low band sweep of the 8569B - probably 10MHz - 1.3GHz, or 1.55GHz max. The low band on the 8569B is 10MHz to 1.8GHz in full band sweep - the 8444A cannot go that high, so you cannot use full band sweep, but can set the 8569B to sweep from 10MHz to 1.5GHz in the MHz per div sweep mode. An external sweep trigger is required to sync the sweep, this should come from the 8569B.
Don Bitters |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Re: Fitting rack ears to ageing HP equipment
Good work! You can “store” the removed trim wrapped in wax paper to reduce the chances of it sticking to anything and everything. Some day you or someone else may want one of those.? Jeremy? On Mon, Nov 11, 2024 at 7:16?PM Tim Barrett K9VB via <timbarrett=[email protected]> wrote:
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Re: Can an 8444A be used with an 8569B?
开云体育Hi James, ? You have the first LO output on the back panel of your 8569B, but you need the 059 option for the 8444A which is a 500 MHz internal source to the 8444A. The first IF of the 8569B is 2050MHz, making it compatible. ? I already owned an 8569B and had out of curiosity tested the 8444A opt 059 and from memory, it worked very well. But since I already had a VNA, I didn't really need this 8444A opt 059, which I sold along with my 8569B. ? Yves De?: [email protected] <[email protected]> De la part de James55 via groups.io ? ?Hello everyone.? |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Re: Application and Service Notes on HPWiki - Update
开云体育Thank You, amazing. ? Fra: [email protected] <[email protected]> P? vegne af Wolfgang Schraml via groups.io ? Hello, ? It's been a while since I provided a status update on the ongoing Applications and Service Notes project. ? Application Notes: There are close to 2,400 now. I pretty much exhausted all known (to me) online archives to collect more. ? Service Notes: After another sync with Keysight's repository over the weekend, HPWiki has almost 5,800 notes now. ? Please contact me if you have any documents that haven't been published yet (especially service notes for older HP equipment). I am sure there are vast, untapped archives in someone's basement. ? Best regards, Wolfgang Schraml KI7PFX |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Re: Application and Service Notes on HPWiki - Update
开云体育Vielen Dank, Wolfgang!Wow! --MfG Tom -- Prof. Thomas H. Lee Allen Ctr., Rm. 205 420 Via Palou Mall Stanford University Stanford, CA 94305-4070 On 11/11/2024 4:06 AM, Wolfgang Schraml
via groups.io wrote:
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Re: HP instrument sticky case panel surface
开云体育The sticky stuff is
likely plasticizer that has separated from the vinyl coating
on the panels. I have had good success using denatured alcohol
and a rag to scrub? off the residue. ?? Bruce Gentry, KA2IVY On 11/11/24 22:50, Calvin Guan via
groups.io wrote:
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Re: Application and Service Notes on HPWiki - Update
On 11/11/24 07:06, Wolfgang Schraml via groups.io wrote:
It's been a while since I provided a status update on the ongoing Applications and Service Notes project.Amazing work as always, Wolfgang. Remember, HPWiki is accessible via the hpwiki.org domain as well. -Dave -- Dave McGuire, AK4HZ New Kensington, PA |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||