FS 3709B 8656A 8657J
Hi! - 8656A uncal, some scratches, no option, working fine, accurate and clean wave generation. 4 key springs missing, but working fine. Original operation and service manual included |
Re: 8566B 1dB scale trace not linear at bottom of screen
I found the 1dB adjustment in the manual
The 1dB step adjustment procedure in the manual involves fixed resistors which I must swap to adjust, the test calls for clipping the trace on the top of the screen and measuring the amount it supposed to go over. I don't believe I noticed anything unusual before with the trace clipped so I think that is ok. 10. Step Gain and 18.4 Mhz Local Oscillator Adjustments |
Re: A bit OT: simulators for children
¿ªÔÆÌåÓýI dunno, maybe by the time I got them in the mid to late 1970's they were either not making them like they used to or I was too advanced by then to be all that interested.? ? ? ? ?Jim Ford? Sent from my Verizon, Samsung Galaxy smartphone -------- Original message -------- From: "sholland via groups.io" <sholland@...> Date: 6/8/21 1:21 PM (GMT-10:00) Subject: Re: [HP-Agilent-Keysight-equipment] A bit OT: simulators for children |
Re: 8566B 1dB scale trace not linear at bottom of screen
As I remember, it is easy, but there are several adjustments that should be done B4 if you want the thing to be overall accurate. I think you can just touch up the attenuation and get off with out touching the LOG amp or VIDEO amp adjustments. These are a bit more time consuming.
toggle quoted message
Show quoted text
Cheers! Bruce Quoting DW <wilson2115@...>: The replies are appreciated. |
Re: 8566B 1dB scale trace not linear at bottom of screen
On Tue, Jun 8, 2021, 6:29 PM Steve - Home <steve-krull@...> wrote:
Same here with 10MHz output from my HP 8665A. |
Re: 8566B 1dB scale trace not linear at bottom of screen
¿ªÔÆÌåÓýI just ran that scenario on my 8566B and the trace does not start to fall off but tracks the sig gen output all the way.?Steve WB0DBS On Jun 8, 2021, at 4:20 PM, DW <wilson2115@...> wrote:
|
2 files uploaded
#file-notice
[email protected] Notification
The following files have been uploaded to the Files area of the [email protected] group.
By: Ken Eckert <eckertkp@...> |
Re: Scope Probe parts
You might check the catalog at probemaster.com
These are not Agilent/HP probes, but their own OEM designs, but there's some chance that they will have accessories which will fit your probes.? I found, a few years ago, that their screw-in probe tips are a good fit for the probes on the venerable HP 8405A vector voltmeter (and are much less expensive than new-old-stock HP). |
Re: 8566B 1dB scale trace not linear at bottom of screen
This is most probably an 8566 adjustment problem. Look over the adjustment procedure and you will find a section where the attenuators are adjusted. I'll try to find time to look up the exact section, but I remember doing this and correcting similar errors.
toggle quoted message
Show quoted text
Quoting DW <wilson2115@...>: Here is a thought, if someone with a 8566 could reproduce my results by injecting a -20dBm 10 Mhz signal and setting the reference level to -20dB and set the scale to 1dB. Then with the signal generator start dropping the signal from -20dBm to -30dBm in 1dB increments. Does the trace start to fall off towards the bottom of the screen compared to 2dB and 5dB? |
Re: 8566B 1dB scale trace not linear at bottom of screen
Here is a thought, if someone with a 8566 could reproduce my results by injecting a -20dBm 10 Mhz signal and setting the reference level to -20dB and set the scale to 1dB. Then with the signal generator start dropping the signal from -20dBm to -30dBm in 1dB increments. Does the trace start to fall off towards the bottom of the screen compared to 2dB and 5dB?
|
Re: Capturing screenshots on 8934C
¿ªÔÆÌåÓýHi, ? I found that for screen capture about 8924C? ? BTS software ? ? De?: [email protected] <[email protected]> De la part de w9dkc ? Sorry, yes. 8924C |
Hp8558b Spectral analyzer (1/2)
hello,
i have repard the displays This analyzer never allowed me to display anything except once , with a generator and a 5v signal which is a bit strong May you tell me if the?if the BNC connector has been replaced by an N. the plug information is not clearly visible? ---> see picture May you tell me if the frequency scanning operation seems normal to you (I have repaired the displays)? --->see the vid¨¦o Thank's for your returns cdt |