HP Equipment for sale
Greetings all, I need to make some room in my lab again (happens too often) , so I have the following equipment for sale: * HP 8566B Spectrum Analyzer with interface cables - $500 * HP 8902A Measuring
By
Joe / KN5U
·
#104681
·
|
Craigslist HP 8566B Indianapolis
Not mine, but I thought someone might be interested https://indianapolis.craigslist.org/ele/7097424406.html Wally KC9INK
By
Wallace Gasiewicz
·
#104680
·
|
Re: Anyone out there fix a partially working 334A I need desperately to get it up and running!
I have both of those models as well that I purchased very inexpensively at an estate sale a few years ago and this conversation has prompted me to drag those out and see the operational status of
By
n4buq
·
#104679
·
|
Re: Anyone out there fix a partially working 334A I need desperately to get it up and running!
Not that it means anything but I do see a neon glow from the photo cells and it appears to be glowing bright. It looks as if someone has worked on this thing at some point because wire positions are
By
Steve
·
#104678
·
|
Re: HP54603B Software Gremlins
Hi Andreas, There is two different Non-volatile/zero-power ram chips in the module. Both have their own internal backup battery. So the battery in one of them is probably bad. I would replace both, as
By
Askild
·
#104677
·
|
Re: HP54603B Software Gremlins
Hi Matthew, the self test menue has an explicit function that tests RAM and it runs thru without error messages. The problems seem to occur in the nonvolatile memory of the HP54657A module. The
By
DG7RBN
·
#104676
·
|
Re: Hints on removing burned tantalum residue
Dave, This looks way better, and might now work, but if it was mine I would clean on it some more. Looking at your hi res photo, there is still some crud around the anode of CR8, around the pin 1 and
By
Kurt Swanson
·
#104675
·
|
Re: Hints on removing burned tantalum residue
Hi Kurt, Thanks for great suggestions. I tried the following on the board and am ready to replace capacitor and start testing. 1) Isopropyl Alcohol and Q tip. Mixed results. 2) Xylene (goof off) is
By
Dave Miller
·
#104674
·
|
Re: Optiion upgrade HP 8753C/B (CRT Focus)
I've seen reports of bad trimpots on the XY board causing display issues on the 8753A/B. However I had a B with CRT issues and didn't find any bad pots. It did respond well to CRT rejuvenation and I
By
Roger Henderson
·
#104673
·
|
Re: Optiion upgrade HP 8753C/B (CRT Focus)
In the future, clean the boards with 100% alcohol and blow dry with compressed air. Best to wash off with de-ionized water but the alcohol alone will work.? Do a final rinse with the alcohol after
By
[email protected]
·
#104672
·
|
Re: 334A
I could help you with that.? Can you tell me the problem?? Is it just the oscillator or the receiver/analyzer or do you not know? George Hnatiuk EMAIL:? ghnatiuk@...
By
[email protected]
·
#104671
·
|
Re: Hints on removing burned tantalum residue
Dave, I do quite a bit of work on IFR service monitors, and have seen this problem many times, both with tantalum and aluminum electrolytics.? I use alcohol and toluene as solvents, and find that I
By
Kurt Swanson
·
#104670
·
|
Re: Anyone out there fix a partially working 334A I need desperately to get it up and running!
I'm sorry Michael, I misremembered. Before I looked in the manual, I remembered lamps, of some sort, and CdS photoresistors, and it registered as a choppers. It is actually a Wien Bridge. Three of the
By
Chuck Harris
·
#104669
·
|
Re: Anyone out there fix a partially working 334A I need desperately to get it up and running!
Collective wisdom, y'all. Stay safe...now that Jzonsson de Peffel also got ill, I am starting to worry a bit. To me, he appeared as the pinnacle of a healthy happy strong man... With best regards Tam
By
Tam Hanna
·
#104668
·
|
Re: Anyone out there fix a partially working 334A I need desperately to get it up and running!
The 334 has an Automatic Nulling (A6 board) circuit which uses lamps and a single detector. I see no chopper.
By
Michael A. Terrell
·
#104667
·
|
Re: Anyone out there fix a partially working 334A I need desperately to get it up and running!
I haven't used it in a while, I've been using a leader LDM-170 but feel more confident in triusting the 334A. First problem is that you can't "Set" anything unless you have an extremely high voltage
By
Steve
·
#104666
·
|
Re: Hints on removing burned tantalum residue
Guys, Just in case it helps, the names Marconi Instruments / IFR / Aeroflex / Cobham / Viavi are all historical parts of the same company from 1998 onwards. With regards to IFR, this operation was/is
By
nigel adams
·
#104665
·
|
Re: Hints on removing burned tantalum residue
Hi Roy, /g/Marconi-Test-Instruments I have been getting some good information there. Dave wrote: -- 72 de Dave VE7HR
By
Dave Miller
·
#104664
·
|
Re: Hints on removing burned tantalum residue
Hi Dave: If you could post the links you found, that would be great. There appears to be many things associated with the names IFR and Aeorflex Cheers and best wishes. Roy
By
Roy Thistle
·
#104663
·
|
Re: 427A volt meter
I didn't mean to sound critical but I think I did, my apologies. The lack of mercury cells is a PITA. Lots of stuff used them and its often hard to find a substitute.
By
Richard Knoppow
·
#104662
·
|