¿ªÔÆÌåÓý

Date
Re: Interesting power supply issue!
Connector miskeyed?? Off by one?? bad? Any idea what line is shorted?? Resistance with the power supply off but plugged into the backplane? Guesses. Harvey
By Harvey White · #143720 ·
Interesting power supply issue!
I have an 8711B where the power supply runs when out of the chassis but when plugged in it keeps trying to start as if there is a short. I have determined that the supply acts this way when the small
By Peter Gottlieb · #143719 ·
Re: N9020A
These MXA options are ridiculously expensive for a hardware that is included on analyzer. Ing. Patricio A. Greco Taller Aeron¨¢utico de Reparaci¨®n 1B-349 Organizaci¨®n de Mantenimiento Aeron¨¢utico
By Patricio A. Greco · #143718 ·
Re: N9020A
Ok, *that* is compelling functionality. -Dave -- Dave McGuire, AK4HZ New Kensington, PA
By Dave McGuire · #143717 ·
Re: N9020A
Here's the datasheet for the N9020A? MXA analyser Keysight N9020A Datasheet (testequipmenthq.com) ( https://www.testequipmenthq.com/datasheets/Keysight-N9020A-Datasheet.pdf ) It may be the case that
By jmr · #143716 ·
Re: N9020A
And hopefully they will stay there, until there's a *real* need to move to something different. It hasn't been a limitation for my work, but see below.
By Dave McGuire · #143715 ·
Re: N9020A
All of the 15-20 year old E4440A PSA analysers are still in use at work despite the ~2 minute boot up time. There's quite a few MXA and PXA analysers at work as well. A fairly decent analyser will
By jmr · #143714 ·
Re: Re-capping an HP-130 Scopes
You won't be able to set up the power supplies by themselves, the other rails depend on the -150V rail, which has the voltage reference tube. Pulling the 6AQ5 (V17 in the pdf manual) would be enough
By factory · #143713 ·
Re: N9020A
The startup time of the 70900B in my lab is about 9 seconds. This is what happens when something is effectively a solved problem and all that's left to "improve" is the production cost. And, well, of
By Dave McGuire · #143712 ·
Re: N9020A
This is getting a bit silly now. The boot time for the classic Agilent E4440A PSA spectrum analyser is quite long This was the industry standard spectrum analyser since 2001 until the PXA/MXA
By jmr · #143711 ·
OT: Physik Instrumente docs?
Please forgive the off-topic post, but I know of no greater concentration of technical knowledge than this one. I am looking for documentation for some Physik Instrumente piezo nanopositioner
By Dave McGuire · #143710 ·
Re: N9020A
Not me, I know enough to have stayed away from it for my whole career. I'm not a patient man. Ignoring its fragility and instability, many of its problems can be sidestepped by not connecting it to a
By Dave McGuire · #143709 ·
Re: 5342A: sometimes counts, sometimes not
And yes, it needs a rather 'stiff' 10 MHz ext ref, I think I feed mine 12 dBm or so (subtract some coax attenuation though) Wilko
By Wilko Bulte · #143708 ·
Seeking HP 80000 Data Generator (aka 2900A) system software
I'm looking for the system software for a HP 80000 [2900A]. If anyone has the 3.5" disks but not the equipment to read them, I can copy the LIF disks and archive them for posterity. (My recollection
By Brian Davis · #143707 ·
Re: 5342A: sometimes counts, sometimes not
Does selecting the selftest display 75 000 000 ? Without a reliable 10 MHz clock int or ext the CPU does not run. Essentially nothing works properly. The switch for int/ext has been known to become
By Wilko Bulte · #143706 ·
Re: N9020A
True, many Windoze things may be run using wine +....otherwise lets keep it that way as virus writing by the "disruptors" is minimal...let them go after Apple and MS...and lets not forget big brother
By Ren¨¦e · #143705 ·
Re: N9020A
That's a pretty laughable statement today Jim. Even my CPAP machine (which is also certified as a hospital ventilator) runs Linux. It was easier to get it through FDA certification than Windows, from
By Dave McGuire · #143704 ·
Re: N9020A
I'm a design engineer. I've held a ham radio license since I was a teenager in the 1980s. I don't think that's relevant to this conversation. You'll find that most people with more than a passing
By Dave McGuire · #143703 ·
Re: N9020A
Inertia.? Linux doesn't have critical mass.? ? ? ? Jim Ford?Sent from my T-Mobile 4G LTE Device
By Jim Ford · #143702 ·
Re: Re-capping an HP-130 Scopes
Thanks David, all precious suggestions. I'll get a light bulb of suitable wattage and start disconnecting the HV section. I am still confused about how to interpret the board connection on valve
By Bepi · #143701 ·