¿ªÔÆÌåÓý

Date
Re: checking line module setting for 110V / 220V
I used a little hook like the ones you can buy at a hardware store and glued it into a small plastic rod Sent: Friday, May 27, 2022 1:29 PM To: [email protected] Subject: Re:
By Lothar baier <Lothar@...> · #126682 ·
Re: checking line module setting for 110V / 220V
Most of my (many) items of HP gear arrived in the UK from the USA so I've met this issue a few times, what I do is: Check that nothing is bent/twisted, take a pair of thin(ish) nosed pliers - with
By Adrian Nicol · #126681 ·
Re: checking line module setting for 110V / 220V
Tom, Give it a tug - they¡¯re in there pretty tight! I just pulled one to be sure and unless someone has damaged something it should pull straight out. Steve K.
By Steve - Home · #126680 ·
Re: checking line module setting for 110V / 220V
there is small hole on card use a hook and pull, swinging the card from side to side There is no locking except fuse lever
By §¥§Þ§Ú§ä§â§Ú§Û §À§â§î§Ö§Ó · #126679 ·
Re: checking line module setting for 110V / 220V
As I recall, there should be a little hole in the small PC Board. Hook it with a Small Screwdriver or anything else you can hook it with, and pull. Regards Bill Lauchlan Sent: Friday, May 27, 2022
By bill.lauchlan171@... · #126678 ·
checking line module setting for 110V / 220V
Hi folks, mayby I'm stupid, but I need guidance. I want to make sure my HP85101 is set for 220V before connecting it to mains and powering it up. The line module seems pretty much standard across the
By tom_iphi · #126677 ·
Re: 8662A - a warning about dangerous service directions
Hi George, This is not an issue with the loads being disconnected. When the overvoltage condition exists, HP advice is to bypass the safety shutdown and measure the voltages. With the normal loads in
By Dmitry Teytelman · #126676 ·
Re: Info Need on a RF FET for a Agilent E4438C signal generator
I used this one for a similar job, worked fine, didn't need to modify the matching networks, https://www.digikey.ca/en/products/detail/macom-technology-solutions/XF1001-SC-0G00/5872554 You won't get
By Ovidiu Popa [Business] · #126675 ·
Re: 8662A - a warning about dangerous service directions
Hi Dmitry Whilst I share your concerns may I say that the HP fault finding guidance is based around having a set of their 8622A or 8623A PCB card extenders available. Under most circumstances using
By george edmonds · #126674 ·
Re: first post - new home lab - tips on using HP/Agilent gear
I replace the 75 ohm resistors that are in series with the output connectors with 50 ohm. The Inputs on the amps that I convert are high impedance, with loop through so I can easily configure a unit
By Michael A. Terrell · #126673 ·
Re: 8662A - a warning about dangerous service directions
Dmitry, It always puzzled me that the manual advised you to bypass the over-voltage protection shutdown in the situation of a potentially damaging over-voltage condition. Seems to me that is only
By Tony · #126672 ·
8662A - a warning about dangerous service directions
Hello, During a recent repair my 8662A went into shutdown due to the high input voltage at the linear regulator (A7A1) input. Service sheet 56 directs one to ground the collector of A7A1Q16 and then
By Dmitry Teytelman · #126671 ·
Re: WTB: 5265A Digital Voltmeter for HP 5245L Electronic Counter.
Hi Stephen, do you still have the 5265A for sale? im in Australia, thanks Ben
By bencmansfield@... · #126670 ·
Re: HP/Agilent/Keysight 8478B thermistor mount
Yes 8478B is a transfer power standard for 7mm connectors . It¡¯s very stable , the matching is not the best but with a good VNA are used as transfer standard on most national lab. The efficiency are
By Patricio A. Greco · #126669 ·
Re: HP/Agilent/Keysight 8478B thermistor mount
If it was used in a standards lab it more than likely has option H01 which guarantees a VSWR < 1.05 at 50MHz , usually either the 8478B-H01 or 478A-H75 or H76 are used for the power level accuracy
By Lothar baier <Lothar@...> · #126668 ·
Re: HP/Agilent/Keysight 8478B thermistor mount
This one came from an auction at McDonnell Douglas plant in St. Louis - It was in their standards lab - a long time ago. AFIK the "B" version is the only one available from HP Cheers! Quoting Lothar
By Bruce · #126667 ·
Re: HP/Agilent/Keysight 8478B thermistor mount
I haven¡¯t seen any 8478B used as transfer standard , we used them with some special option to calibrate the 50MHz reference on 43x series meters , for sensor calibration we used a weinschel system2
By Lothar baier <Lothar@...> · #126666 ·
Re: Limits of the Port Extension on the Cal screen for calibrating at end of cable
Could you have used a single point frequency measurement n the VNA? I know the 8510 will do that. But I am sure the experience was educational - thanks for the education - it would have taken me a bit
By Bruce · #126665 ·
Re: HP/Agilent/Keysight 8478B thermistor mount
I actually have one of these and treat it VERY carefully whenever I use it - which is infrequently Cheers! Bruce Quoting Lothar baier <Lothar@...>:
By Bruce · #126664 ·
Re: HP/Agilent/Keysight 8478B thermistor mount
I certainly would call $14K outrageously expensive. Cheers! Bruce Quoting Lothar baier <Lothar@...>:
By Bruce · #126663 ·