Re: Mounting HP Iron in 19" Racks
Angles from old bed frames. Brilliant! I need some and never thought of those and they're indeed ubiquitous!
toggle quoted message
Show quoted text
Thanks, Barry - N4BUQ I used to do this with scrounged angle iron from bed frames people would throw |
Re: Mounting HP Iron in 19" Racks
I used to do this with scrounged angle iron from bed frames people would throw out on trash day.? Some are pretty wide and I can attest to the wood strip method to keep things centered.? A sawzall makes quick work of cutting them.
toggle quoted message
Show quoted text
Peter On 3/30/2024 7:10 PM, Ed Breya via groups.io wrote:
I have a bunch of fairly heavy aluminum 90 degree angle-iron pieces scrounged up long ago. They are about 2" by 3/16" flats by 30" long, and easy to drill holes anywhere and attach with the usual 10-32 screws into the side members of almost any rack. Usually it's enough to just support the side rails of the gear firmly, from front to back. I put the heaviest items on the rails, and stack lighter gear on them, so only a few big items are actually mounted, and serve as shelves for the rest. It's easier to reconfigure too, unless you need to relocate the big stuff. |
Re: HP-1421A Q109 Voltages
I got a chance to test the circuit just a bit.? I placed a 47k resistor between the base of Q109 and ground.? That caused the lamp to illuminate so the transistor is still good.? I just need to determine why the base voltage is being held at or below the emitter voltage. Thanks, Barry - N4BUQ
|
Re: Mounting HP Iron in 19" Racks
The cantilever shelves work great. Especially for the smaller stuff, like putting two 1/2 width units together. I have used a lot of Navepoint stuff in the past. This is an option that I like for 3U-4U type boxes.? They also sell the cantilever style shelves and the sturdier 4-post type shelves (sliding and static styles). Of course, looks like their prices are up since I bought from them last. Always worthwhile to keep an eye on fleabay for cheap lots. -Michael Bierlein On Sat, Mar 30, 2024 at 19:51 Dave Daniel <kc0wjn@...> wrote:
|
Re: HP8560a smoke came out
Rifa caps are not happy with high voltages.? Could you adjust your solar panel inverter to only 240 volts?
toggle quoted message
Show quoted text
Harvey On 3/30/2024 6:51 PM, glenn percy via groups.io wrote:
Thanks Henning re *delta marker*. Been a while since I operated this SA. I just confirmed thats the level issue. |
Re: Mounting HP Iron in 19" Racks
¿ªÔÆÌåÓýI've been using these (from Amazon) for years. They work pretty well: AC Infinity Vented Cantilever 2U Universal Rack Shelf, 16" Deep, for 19¡± equipment racks. Heavy-Duty 2.4mm Cold Rolled Steel, 100lbs Capacity.? https://a.co/d/09Sckik DaveD On Mar 30, 2024, at 17:23, Dave Miller <ve7hr@...> wrote:
|
Re: Mounting HP Iron in 19" Racks
¿ªÔÆÌåÓýThis is a better solution than mounting ears.It is probable that the ears alone will not properly support the weight of the gear. Glenn On 3/30/2024 5:23 PM, Dave Miller
wrote:
I have run out of floor and bench space and it's time start filling up the racks I have stored away. :-( -- ----------------------------------------------------------------------- Glenn Little ARRL Technical Specialist QCWA LM 28417 Amateur Callsign: WB4UIV wb4uiv@... AMSAT LM 2178 QTH: Goose Creek, SC USA (EM92xx) USSVI, FRA, NRA-LM ARRL TAPR "It is not the class of license that the Amateur holds but the class of the Amateur that holds the license" |
Re: HP8560a smoke came out
Thanks Henning re delta marker. Been a while since I operated this SA. I just confirmed thats the level issue.
Re the cap across the mains, that's what i suspected initially as I had it happen on other? HP test gear.? Getting to that area though appears very difficult to confirm that's all it is. The mains voltage here can rise to over 250v on a sunny day, as I have solar panels on the roof. Glenn |
Re: Mounting HP Iron in 19" Racks
Forgot to mention, most gear should not be mounted only by the front ears or flanges - only the very lightest and shortest (front to back) items are safe this way. Sides and back support is needed for the typical big old gear. Use judgement, and think about the vector forces on everything.
Ed |
Re: Mounting HP Iron in 19" Racks
I have a bunch of fairly heavy aluminum 90 degree angle-iron pieces scrounged up long ago. They are about 2" by 3/16" flats by 30" long, and easy to drill holes anywhere and attach with the usual 10-32 screws into the side members of almost any rack. Usually it's enough to just support the side rails of the gear firmly, from front to back. I put the heaviest items on the rails, and stack lighter gear on them, so only a few big items are actually mounted, and serve as shelves for the rest. It's easier to reconfigure too, unless you need to relocate the big stuff.
So, you don't really need a shelf pan, but be sure the gear can't move too far side to side and fall through. The wide enough angle stock mostly assures this. I drop in wooden shims on the sides if there's any doubt. Also be sure the rack is stout enough to not bow open - sometimes you need cross pieces here and there to hold the sides together Ed |
Re: Mounting HP Iron in 19" Racks
I have some of the front mount shelves but the cheap?ones won't?support the?nice HP iron. They?deflect too much. That picture was for the Mainframe?SRS-4-F. I can get them at my local supplier in Vancouver?BC. So it's?an offshore import. You can find?ones that are similar on Amazon but prices seem much higher. I think I will grab?a couple to test out. Dave VE7HR On Sat, Mar 30, 2024 at 2:28?PM Peter Gottlieb <hpnpilot@...> wrote: I use equipment shelves that only mount from the front, but the one you show is --
72 de Dave VE7HR |
Re: Mounting HP Iron in 19" Racks
I use equipment shelves that only mount from the front, but the one you show is better mechanically.? Where do you get them?? Do you have a part number?
toggle quoted message
Show quoted text
Pter On 3/30/2024 5:23 PM, Dave Miller wrote:
I have run out of floor and bench space and it's time start filling up the racks I have stored away. :-( |
Mounting HP Iron in 19" Racks
I have run out of floor and bench space and it's time start filling up the racks I have stored away. :-(
Unfortunately most of the equipment does not have mounting ears. Last time I looked at them they are hard to find and very expensive. What's everyone thoughts about using 4 post ventilated shelves like this? They are rated 120 kg a shelf. I can source them locally cheaper and faster than a set out mounting ears on Fleabay with shipping. And I can adjust the height instead of getting multiple sizes of ears. It's also easier to wrestle something on a shelf than mount it in a rack with screws. Or at least that is my limited experience. And If I want put another piece in rack it seems easier. What do the experts have to say? Thanks Dave? VE7HR |
Hp 8720ES error help
¿ªÔÆÌåÓý
Hello I am trying to get a 8720ES working. It has a CPU board fault. The CPU board start some but not fully.
I get an error saying:
Please stand by- Error INST
This error I cannot find info on anywhere. Maybe someone can help me ?
best regards Peter
|
Re: HP 427A no DC offset adj. pot
Probably so Paul. ?I do wonder if the lack of manuals for this particular version of the 427A is because it was a military/govt. version that is just now being phased out. ?Agree on the beat up surplus. ?I just looked at a couple of pieces up for auction too rough for me. ?I will say however, over the past two years I've picked up a HP 8601A that had been stored in a hermetically sealed bag, a Sencore SC-61 O'scope that was literally new/unused in its original box (probes and all), as well as a Boonton 92EA and Sencore LC-53 that were in great shape. ?Maybe between here and over at antiqueradios someone will come through with a manual for this version.
Leon... |
Re: HP8560a smoke came out
If you are in 230V country sure I would bet on explosion of RIFA caps in the power supply. Not difficult to repair it, just power supply board needs to be removed from SA. Whe you are in, check also condition of electrolytic caps. Regarding level of calibration signal, you have enabled delta-marker not absolute value measurement. This is the reason to show that "high" level. Vladimir Komu [email protected]
Kopie
Datum Sat, 30 Mar 2024 12:28:26 +0000
±Ê?±ð»å³¾¨§³Ù Re: [HP-Agilent-Keysight-equipment] HP8560a smoke came out
Don't know that exact model, but could it be mains power I/P filter / Rifa line filter caps? On 30/03/2024 04:11, glenn percy via
groups.io wrote:
New member here. |
Re: HP8560a smoke came out
¿ªÔÆÌåÓýDon't know that exact model, but could it be mains power I/P filter / Rifa line filter caps?On 30/03/2024 04:11, glenn percy via
groups.io wrote:
New member here. |