Re: HP 8662A Power up - overvoltage shutdown
A question or so: 1) is the equipment supposed to run at 230 VAC?? Are you in a region where you could get 240?? Is it specified for that? 2) any idea if it's a supply triggering this, or a general
By Harvey White · #126556 ·
Re: HP 8662A Power up - overvoltage shutdown
Digging a bit more I find that the PSU will start successfully at 220V AC and at 225V AC. But at 230V AC and above it throws and over-voltage error. Not quite sure where to take it now... Tony
By Tony · #126555 ·
Re: first post - new home lab - tips on using HP/Agilent gear
If I'm not mistaken, the designer of the 8671/8672 is (or at least was) on this mailing list. Perhaps he'll chime in. -Dave
By Dave McGuire · #126554 ·
Re: HP 8662A Power up - overvoltage shutdown
I have not measured it to be frank. But both of the above tests were with the variac set to 230V - either powering on the instrument and turning it up gradually, or otherwise setting the variac to
By Tony · #126553 ·
Re: HP 8662A Power up - overvoltage shutdown
Hi Tony What is your actual mains voltage? G Edmonds
By george edmonds · #126552 ·
HP 8662A Power up - overvoltage shutdown
Hi, I'm hoping somebody can advise me how to approach a power-on issue with my HP 8662A signal generator. It came with a faulty power supply and I went through a detailed fault finding process and
By Tony · #126551 ·
Re: 53181A 3 GHz prescaler from China
Many years ago I remade/copied the original Agilent card. It works fine. I think the Chinese did the same thing industrially.
By maurit · #126550 ·
Re: first post - new home lab - tips on using HP/Agilent gear
Are the video amplifiers 50 or 75 ohm?
By Michael A. Terrell · #126549 ·
Re: Frequency range of HP 5352B frequency counter
Hi Dave, There is some info in these posts: /g/HP-Agilent-Keysight-equipment/message/111396 /g/HP-Agilent-Keysight-equipment/message/103664 Seems as the only
By Askild · #126548 ·
Re: HP 3465A offset when input shorted
On Mon, May 23, 2022 at 04:23 PM, Chris Smith wrote: > > Hi all, > > Just obtained a rather sick HP3465A (the 4.5 digit one, not the big 6.5 > digit unit). It is functioning but there is a one sided
By Ozan · #126547 ·
Re: first post - new home lab - tips on using HP/Agilent gear
Generally use the distribution amplifier outputs it¡¯s the best way to do it and also make sure to terminate the unused outputs ! As far as the 8671B concerns, turn on the unit and let it warm up,
By Lothar baier <Lothar@...> · #126546 ·
Re: 53181A 3 GHz prescaler from China
I bought one a while back for my 53132A. I haven't done much testing of it, but it seems to work just fine. Keith
By Keith · #126545 ·
Re: HP 8640 Bad Frequency Counter
Sounds like one or more of the fingers in the range switch have let go of their supporting disc. If that's the case, they're probably wandering around in the bottom of the cabinet so carefully
By n4buq · #126544 ·
first post - new home lab - tips on using HP/Agilent gear
Hi, I recently cheaply (< $700) acquired working (they power on) set from a deceased engineer's estate sale in the US: * HP 8566B 100 Hz - 22 GHz spectrum analyzer (two sections) * HP 8671B CW
By Samudra N3RDX S21X · #126543 ·
HP 8640 Bad Frequency Counter
Hello All, Can someone point me in the right direction? The HP 8640 has output on all ranges. The frequency counter is accurate on the 4 to 8 MHZ range ONLY. ALL other ranges are way off. Any ideas?
By Phil N6WKZ · #126542 ·
Re: 53181A 3 GHz prescaler from China
I haven¡¯t bought any of them so I cant attest to how well they work but $40 aint all that much money to give it a try
By Lothar baier <Lothar@...> · #126541 ·
Re: HP 8640B stiff main tuning
Some have reported great success using Tri-flow as a lubricant on hardened grease that TenTec used on their vfos.? Reports have it that TenTec used whatever tractor grease the farm store had on the
By Randy.AB9GO · #126540 ·
53181A 3 GHz prescaler from China
Hello All, I am thinking about getting a 3 GHz prescaler board for the HP 53181A from China.? They are only about $40US.? How well do they work? Tom N3AJA
By Tom B · #126539 ·
Re: Frequency range of HP 5352B frequency counter
wrote: Thank you. Do you know if it¡¯s possible to extend the frequency range to 46 GHz? Not that I can think of a use between 40 & 47 GHz, nut if an upgrade is possible, I might be interested. Dave
By Dr. David Kirkby, Kirkby Microwave Ltd · #126538 ·
Re: Frequency range of HP 5352B frequency counter
Yes the 5352 was 40GHz however HP used the back panel for different models not just the 52 , the 5361B pulse counter for example had options for 26 and 40GHz and the 5352 had options for 46GHz Sent:
By Lothar baier <Lothar@...> · #126537 ·