¿ªÔÆÌåÓý

Date

Re: Spaces before units (Re: [HP-Agilent-Keysight-equipment] HP/Agilent/Keysight version of Tek Wiki?)

 

On 2022-01-08, at 23:11, Dave McGuire <mcguire@...> wrote:

The big issues come when line wrapping splits the units from their quantities. I can't stand that.
(The non-breaking space U+00A0 was invented for avoiding such line breaks.
As with ? and ¦¸, that is easier to type on some platforms than on others.
Unfortunately, my mail composer doesn¡¯t seem to like it at all.)

Gr¨¹?e, Carsten


Re: Spaces before units (Re: [HP-Agilent-Keysight-equipment] HP/Agilent/Keysight version of Tek Wiki?)

 

AS / ISO 1000:1998 is the standard for display of SI units. It says there should be a single space between the numeral and the unit-cum-multiplier.
Is that a current standard?
No.
Just to clarify that ¡°No¡±: ISO 1000 was a standard promulgated by the International Organization for Standardization (ISO).
*They* are saying this no longer is a current standard, having been replaced by ISO 80000-1.

Whether ISO (which has allied with IEC here), or BIPM, or (for me) PTB in Germany is the ¡°authoritative¡± organization for Metrology can be debated ad nauseam.
I tend to use both BIPM¡¯s SI Brochure (the English language half of it [1]) *and* ISO/IEC 80000 in my work.
Fortunately, they generally agree (with the little drawback that ISO is really slow updating some of the standards).
The SI Brochure of course has the advantage that it is available at no cost.
On the other hand, ISO/IEC 80000 goes into more details on some domains of expertise (you still need weird stuff like ISO 7027 in addition to that, though).

Gr¨¹?e, Carsten

[1]:
[2]:


Re: Spaces before units (Re: [HP-Agilent-Keysight-equipment] HP/Agilent/Keysight version of Tek Wiki?)

 

On 1/8/22 4:39 PM, Dr. David Kirkby, Kirkby Microwave Ltd wrote:
>> AS / ISO 1000:1998 is the standard for display of SI units. It
says there should be a single space between the numeral and the
unit-cum-multiplier.
>
> Is that a current standard?
No.
During the start of the pandemic, the National Physical Laboratory (NPL) put a lot of courses available for free - normally they range from free to nearly
?1,000 GBP. I did every one of them. I know it was clearly stated there that there should be a space between the numerical part and the unit.
Well that's annoying, as it seems to have been a matter of someone's personal preference. One that I don't happen to share. ;)

The big issues come when line wrapping splits the units from their quantities. I can't stand that.

-Dave

--
Dave McGuire, AK4HZ
New Kensington, PA


Re: Spaces before units (Re: [HP-Agilent-Keysight-equipment] HP/Agilent/Keysight version of Tek Wiki?)

 

On Sat, 8 Jan 2022 at 07:17, Carsten Bormann <cabocabo@...> wrote:
On 8. Jan 2022, at 05:40, Dave McGuire <mcguire@...> wrote:
>
>> AS / ISO 1000:1998 is the standard for display of SI units. It says there should be a single space between the numeral and the unit-cum-multiplier.
>
> Is that a current standard?

No.

During the start of the pandemic, the National Physical Laboratory (NPL) put a lot of courses available for free - normally they range from free to nearly
?1,000 GBP. I did every one of them. I know it was clearly stated there that there should be a space between the numerical part and the unit.?

I can¡¯t be bothered, but the following reference is about as authoritative as you would get.?

The International Bureau of Weights and Measures (Bureau International des Poids et Mesures, BIPM) is the intergovernmental organisation through which Member States act together on matters related to measurement science and measurement standards.



--
Dr. David Kirkby,
Kirkby Microwave Ltd,
drkirkby@...

Telephone 01621-680100./ +44 1621 680100

Registered in England & Wales, company number 08914892.
Registered office:
Stokes Hall Lodge, Burnham Rd, Althorne, Chelmsford, Essex, CM3 6DT, United Kingdom


Re: HP 141T CRT Question

 

If anyone wants to play with rejuvenation, I have a B&K 465 CRT Tester/rejuv with all the manuals and adapters that needs a new home. $60 shipped in the US. Pictures on request.

73,
geo - n4ua


Re: HP 141T CRT Question

 

¿ªÔÆÌåÓý

That could be a bad/dirty intensity pot, or the sign of a CRT wearing out. Google for "double-peaking" (although you're not seeing the second peak, which is why the "bad pot" hypothesis is worth looking into).

--Tom
-- 
Prof. Thomas H. Lee
Allen Ctr., Rm. 205
350 Jane Stanford Way
Stanford University
Stanford, CA 94305-4070
On 1/8/2022 08:30, WB4IUY wrote:

I have a 141T mainframe that working, OK, but I noticed if I advance the intensity (brightness) adjustment close to max the intensity falls back off. It doesn't go out, it just gets dimmer. Any ideas on this before I dig into it?

Thanks,
Dave


Re: Spaces before units (Re: [HP-Agilent-Keysight-equipment] HP/Agilent/Keysight version of Tek Wiki?)

 

Wonderful, Chuck. Clarity, as you rightly point out, should be the cherub of greater minds.

If only the editors of journals would agree...

-- Cheers,
Tom

--
Prof. Thomas H. Lee
Allen Ctr., Rm. 205
350 Jane Stanford Way
Stanford University
Stanford, CA 94305-4070

On 1/8/2022 05:57, Chuck Harris wrote:
Ralph Waldo Emerson once wrote:"

A foolish consistency is the hobgoblin of little minds,
adored by little statesmen and philosophers and divines.
With consistency a great soul has simply nothing to do.
He may as well concern himself with his shadow on the wall.

Speak what you think now in hard words, and to-morrow speak
what to-morrow thinks in hard words again, though it contradict
every thing you said to-day.

¡ª 'Ah, so you shall be sure to be misunderstood.'
¡ª Is it so bad, then, to be misunderstood?

Pythagoras was misunderstood, and Socrates, and Jesus,
and Luther, and Copernicus, and Galileo, and Newton,
and every pure and wise spirit that ever took flesh.

To be great is to be misunderstood.

A foolish consistency is the hobgoblin of little minds
adored by little statesmen and philosophers and devines.
With consistency a great soul has nothing to do.
He may as well concern himself with his shadow on the wall."

The convention of putting a space, or not putting a space, between a
number and a unit is about clarity.

It's your writing. If you find it more clear when you put in a space,
then do that. If you find it more clear when you don't put in a space,
then that is what you should do.

It's your writing, and the only payment you are ever going to get for
doing that writing is the pleasure of spending some of your precious
little time on this earth writing... Well, that and the pleasure of
being criticized because you didn't write it the way some reader wanted
to read it.

99% of the time, I choose to not put a space between the number and its
units, because I find the spacing of the fixed pitch typographic fonts
that I prefer, to be rather wide already. Adding a space divorces the
unit from the number. Further, automatic line wrapping algorithms take
no heed of your desire for the number and unit to be together, and often
will put those at the end of a line onto different lines.

Which, rather doesn't improve the clarity of your writing.

-Chuck Harris

On Sat, 8 Jan 2022 08:17:10 +0100 "Carsten
Bormann" <cabocabo@...> wrote:
On 8. Jan 2022, at 05:40, Dave McGuire <mcguire@...> wrote:

AS / ISO 1000:1998 is the standard for display of SI units. It
says there should be a single space between the numeral and the
unit-cum-multiplier.
Is that a current standard?
No.

See ¡ª the ISO/IEC 80000
series has replaced most earlier standards in this space (quantities
and units).

But the rule stands.

ISO 80000-1:2009 Section 7.1.4 has this to say:

7.1.4 Expressions for quantities

The symbol of the unit shall be placed after the numerical value
in the expression for a quantity, leaving a space between the
numerical value and the unit symbol. It should be noted that this
rule also applies to the units per cent, % and per mil, ¡ë. It
should also be noted that, in accordance with this rule, the
symbol ¡ãC for the degree Celsius shall be preceded by a space when
expressing a Celsius temperature.

The only exceptions to this rule are for the units degree, minute
and second for plane angle, in which case there shall be no space
between the numerical value and the unit symbol.
Can¡¯t provide a link, because
hides
most of the document until you pay for it. (Most of ISO/IEC 80000
actually is accessible there because it is in the definitions
sections, which are not behind the paywall. But not this rule.)

If you don¡¯t want to buy tons of ISO standards, the basics of units
and quantities for electrotechnical work have been written up by
Rohde and Schwarz (who used to be the distributor of HP equipment in
Germany a few decades ago, but mostly peddles their own instruments
right now). I found this document, of all places, in their career
section; apparently you are supposed to be able to read, write,
calculate, and clearly express your units if you want to work there:



If you don¡¯t trust URL shorteners, here is the full link:



Mandatory reading.
(The specific rule that there is a space between the number and the
unit is so ingrained that isn¡¯t even spelled out as such here, but is
consistently used in the examples.)

(I don¡¯t like all these rules, just like I don¡¯t always like English
spelling very much :-) But it is the standard¡­ So I don¡¯t meik ahp
mai oun ruulz.)

Gr¨¹?e, Carsten








Re: HP 141T CRT Question

 

Besides the manual method of rejuvinating the CRT, you could
use something like a Sencore CR70 or the more expensive CR7000
which automate the rejuvinating process and tend to be a
bit kinder to the tube. Still have the possibility of killing
the tube though, but they offer multiple levels of rejuvination
so you can optimize the harm/benefit choice. You used to be
able to find CR70s for $50 more or less, but they seem to be
pricier now.

Rejuvination seem to get you somewhere between a few hundred and
a thousand hours or so before it fades again. But that's quite
a lot of usage for a hobbiest.

Full disclosure: I have a CR70 and a double peaking Tek 576 that
I plan to use it on, but it's a ways down the queue. I'll get to
it someday.

On the bright side, 141s are pretty common so it shouldn't be
too hard to find a parts unit or grab a usable CRT if you aren't
successful at rejuvination.

If you ever saw the video from Tektronix on how they built their
scope tubes, it would seem possible to rebuild them. Given
the investment in equipment and skill though along with the
size of the potential market, I can't see how you could break
even, let alone make any money doing that.

Paul

--
Paul Amaranth, GCIH | Manchester MI, USA
Aurora Group of Michigan, LLC | Security, Systems & Software
paul@... | Unix/Linux - We don't do windows


Re: Spaces before units (Re: [HP-Agilent-Keysight-equipment] HP/Agilent/Keysight version of Tek Wiki?)

 

I don¡¯t want to extend this thread indefinitely, but I just ran into exhibit 1 :-)

We generally write microfarads as uF instead of ?F because the latter may be a bit harder to type on some systems, and it is somewhat unlikely to actually need ¡°u¡± (atomic mass units) in conjunction with farads.

Now I ran into a case of hypercorrection [0]:
The manual for a capacitor decade, made by the quite respectable Time electronics [1].
This consistently uses greek prefixes, e.g. in:

¦ÌF = Red
¦ÇF = White
¦ÑF = Yellow

You may need to squint, but the u?? (mu for micro) reverse correction, where we add a little stem to the u to make it a mu, was extended to n?¦Ç (eta for nano) and p?¦Ñ (rho for pico).
You can¡¯t make this stuff up¡­

So please don¡¯t try to be *too* correct.

Gr¨¹?e, Carsten


[0]:
[1]:


Re: HP 141T CRT Question

 

Not controversy to me.? But I did want to point out that the solution has a tradeoff.? Not sure how obvious the tradeoff happens to be.

Harvey

On 1/8/2022 12:31 PM, Mike Feher wrote:
As I said, maybe a "while longer". Why always so much controversy on here? - Mike

Mike B. Feher, N4FS
89 Arnold Blvd.
Howell NJ 07731
848-245-9115

-----Original Message-----
From: [email protected] <[email protected]> On Behalf Of Harvey White
Sent: Saturday, January 8, 2022 12:25 PM
To: [email protected]
Subject: Re: [HP-Agilent-Keysight-equipment] HP 141T CRT Question

Using a booster on a CRT is roughly equivalent to stuffing a new wick in an old candle and lighting both at the same time.

Increasing the filament voltage does make the cathode hotter, but the boosters don't do this for a little bit and try to clean off the cathode surface, they just increase the voltage. Since lifetime of the filament is related to the voltage/temperature, you're shortening the life of the tube.

Of course, that makes an unusable CRT useable, but for only so long.

Always tradeoffs.

Harvey


On 1/8/2022 11:52 AM, Mike Feher wrote:
It has been a long time since I had a 141T. However, I remember back
in the early 60's I worked at a Radio/TV repair shop and often had TVs
with dim video. There used to be a "booster" that would temporarily
fix the problem by increasing the filament voltage, hence the
emission. I do not know if that is feasible on the 141T design but it
may prolong the CRT's usable life a while longer if it is. 73 - Mike

Mike B. Feher, N4FS
89 Arnold Blvd.
Howell NJ 07731
848-245-9115

-----Original Message-----
From: [email protected]
<[email protected]> On Behalf Of Dave McGuire
Sent: Saturday, January 8, 2022 11:35 AM
To: [email protected]
Subject: Re: [HP-Agilent-Keysight-equipment] HP 141T CRT Question

On 1/8/22 11:30 AM, WB4IUY wrote:
I have a 141T mainframe that working, OK, but I noticed if I advance
the intensity (brightness) adjustment close to max the intensity
falls back off. It doesn't go out, it just gets dimmer. Any ideas on
this before I dig into it?
This is "close to" a classic symptom of a CRT with low emission. I believe the classic symptom is for the visible brightness to decrease and then increase again as the intensity control is increased. Chuck can probably explain better here.

-Dave

--
Dave McGuire, AK4HZ
New Kensington, PA














Re: HP 141T CRT Question

 

There is a way to evaluate the CRT. You can use an old TV tube tester and make sure the pins are correct for the tester. Usually these testers are cheap and come with several adaptors for different pin outs. They also can have a booster function that burns off the tube a bit. I don't know if this would work or not. TV pic tube testers are cheap. I just gave away a nice one to someone who works on old scopes and I do have access to 2-3 other units
What tube does the 141 use??? Not sure about the 141.. I have an original US WWII unused CRT that was used in lots of scopes (Box sez EICO, but Heath and others used the tube)
Tube is free but I do not think it would ship well.

Wally KC9INK, located Indianapolis IN


Re: HP 141T CRT Question

 

As I said, maybe a "while longer". Why always so much controversy on here? - Mike

Mike B. Feher, N4FS
89 Arnold Blvd.
Howell NJ 07731
848-245-9115

-----Original Message-----
From: [email protected] <[email protected]> On Behalf Of Harvey White
Sent: Saturday, January 8, 2022 12:25 PM
To: [email protected]
Subject: Re: [HP-Agilent-Keysight-equipment] HP 141T CRT Question

Using a booster on a CRT is roughly equivalent to stuffing a new wick in an old candle and lighting both at the same time.

Increasing the filament voltage does make the cathode hotter, but the boosters don't do this for a little bit and try to clean off the cathode surface, they just increase the voltage. Since lifetime of the filament is related to the voltage/temperature, you're shortening the life of the tube.

Of course, that makes an unusable CRT useable, but for only so long.

Always tradeoffs.

Harvey


On 1/8/2022 11:52 AM, Mike Feher wrote:
It has been a long time since I had a 141T. However, I remember back
in the early 60's I worked at a Radio/TV repair shop and often had TVs
with dim video. There used to be a "booster" that would temporarily
fix the problem by increasing the filament voltage, hence the
emission. I do not know if that is feasible on the 141T design but it
may prolong the CRT's usable life a while longer if it is. 73 - Mike

Mike B. Feher, N4FS
89 Arnold Blvd.
Howell NJ 07731
848-245-9115

-----Original Message-----
From: [email protected]
<[email protected]> On Behalf Of Dave McGuire
Sent: Saturday, January 8, 2022 11:35 AM
To: [email protected]
Subject: Re: [HP-Agilent-Keysight-equipment] HP 141T CRT Question

On 1/8/22 11:30 AM, WB4IUY wrote:
I have a 141T mainframe that working, OK, but I noticed if I advance
the intensity (brightness) adjustment close to max the intensity
falls back off. It doesn't go out, it just gets dimmer. Any ideas on
this before I dig into it?
This is "close to" a classic symptom of a CRT with low emission. I believe the classic symptom is for the visible brightness to decrease and then increase again as the intensity control is increased. Chuck can probably explain better here.

-Dave

--
Dave McGuire, AK4HZ
New Kensington, PA







Re: HP 141T CRT Question

 

Using a booster on a CRT is roughly equivalent to stuffing a new wick in an old candle and lighting both at the same time.

Increasing the filament voltage does make the cathode hotter, but the boosters don't do this for a little bit and try to clean off the? cathode surface, they just increase the voltage.? Since lifetime of the filament is related to the voltage/temperature, you're shortening the life of the tube.

Of course, that makes an unusable CRT useable, but for only so long.

Always tradeoffs.

Harvey

On 1/8/2022 11:52 AM, Mike Feher wrote:
It has been a long time since I had a 141T. However, I remember back in the early 60's I worked at a Radio/TV repair shop and often had TVs with dim video. There used to be a "booster" that would temporarily fix the problem by increasing the filament voltage, hence the emission. I do not know if that is feasible on the 141T design but it may prolong the CRT's usable life a while longer if it is. 73 - Mike

Mike B. Feher, N4FS
89 Arnold Blvd.
Howell NJ 07731
848-245-9115

-----Original Message-----
From: [email protected] <[email protected]> On Behalf Of Dave McGuire
Sent: Saturday, January 8, 2022 11:35 AM
To: [email protected]
Subject: Re: [HP-Agilent-Keysight-equipment] HP 141T CRT Question

On 1/8/22 11:30 AM, WB4IUY wrote:
I have a 141T mainframe that working, OK, but I noticed if I advance
the intensity (brightness) adjustment close to max the intensity falls
back off. It doesn't go out, it just gets dimmer. Any ideas on this
before I dig into it?
This is "close to" a classic symptom of a CRT with low emission. I believe the classic symptom is for the visible brightness to decrease and then increase again as the intensity control is increased. Chuck can probably explain better here.

-Dave

--
Dave McGuire, AK4HZ
New Kensington, PA






Re: HP 141T CRT Question

 

¿ªÔÆÌåÓý

There was some discussion on the TekScopes mailing list.? /g/TekScopes/topic/mechanism_of_crt_double/29888634?p=

?

Dave Wise

?

From: [email protected] <[email protected]> On Behalf Of Bruce via groups.io
Sent: Saturday, January 08, 2022 9:06 AM
To: [email protected]
Subject: Re: [HP-Agilent-Keysight-equipment] HP 141T CRT Question

?

Look on line - there is a piece on CRT restoration. It involves
pulsing the cathode current substantially above rated values to clean
it. It should be done carefully and ONLY after going the CRT set up
procedure to be sure the CRT bias and intensity limit are set properly.


The document is probably on this forum somewhere

FOUND IT - see attached - DO NOT try till you have done the CRT Z axis
adjustments. and if i get some time, I will forward it to you if you
cannot find it.

Cheers!

Bruce

Quoting WB4IUY <wb4iuy@...>:

> HI Dave,
>
> I remember in the days of vacuum tube HV rectifiers, this would
> happen when the rect tube was weak...but in this mostly solid state
> scope, I didn't think that would be the issue. I'll put my nose to
> the ground at swapmeets (and here!) for a spare CRT, just in case.
>
>
>







Re: HP 141T CRT Question

 

Look on line - there is a piece on CRT restoration. It involves pulsing the cathode current substantially above rated values to clean it. It should be done carefully and ONLY after going the CRT set up procedure to be sure the CRT bias and intensity limit are set properly.


The document is probably on this forum somewhere

FOUND IT - see attached - DO NOT try till you have done the CRT Z axis adjustments. and if i get some time, I will forward it to you if you cannot find it.

Cheers!

Bruce

Quoting WB4IUY <wb4iuy@...>:

HI Dave,

I remember in the days of vacuum tube HV rectifiers, this would happen when the rect tube was weak...but in this mostly solid state scope, I didn't think that would be the issue. I'll put my nose to the ground at swapmeets (and here!) for a spare CRT, just in case.



Re: HP 141T CRT Question

 

On 1/8/22 11:45 AM, WB4IUY wrote:
I remember in the days of vacuum tube HV rectifiers, this would happen when the rect tube was weak...but in this mostly solid state scope, I didn't think that would be the issue. I'll put my nose to the ground at swapmeets (and here!) for a spare CRT, just in case.
The emission I'm talking about is that of the CRT's cathode, not something in the power system.

-Dave

--
Dave McGuire, AK4HZ
New Kensington, PA


Re: HP 141T CRT Question

 

It has been a long time since I had a 141T. However, I remember back in the early 60's I worked at a Radio/TV repair shop and often had TVs with dim video. There used to be a "booster" that would temporarily fix the problem by increasing the filament voltage, hence the emission. I do not know if that is feasible on the 141T design but it may prolong the CRT's usable life a while longer if it is. 73 - Mike

Mike B. Feher, N4FS
89 Arnold Blvd.
Howell NJ 07731
848-245-9115

-----Original Message-----
From: [email protected] <[email protected]> On Behalf Of Dave McGuire
Sent: Saturday, January 8, 2022 11:35 AM
To: [email protected]
Subject: Re: [HP-Agilent-Keysight-equipment] HP 141T CRT Question

On 1/8/22 11:30 AM, WB4IUY wrote:
I have a 141T mainframe that working, OK, but I noticed if I advance
the intensity (brightness) adjustment close to max the intensity falls
back off. It doesn't go out, it just gets dimmer. Any ideas on this
before I dig into it?
This is "close to" a classic symptom of a CRT with low emission. I believe the classic symptom is for the visible brightness to decrease and then increase again as the intensity control is increased. Chuck can probably explain better here.

-Dave

--
Dave McGuire, AK4HZ
New Kensington, PA


Re: HP 141T CRT Question

 

HI Dave,

I remember in the days of vacuum tube HV rectifiers, this would happen when the rect tube was weak...but in this mostly solid state scope, I didn't think that would be the issue. I'll put my nose to the ground at swapmeets (and here!) for a spare CRT, just in case.


In search of 14XX-series Plugins for 141T

 

I'm in need of a Horizontal and Vertcial plug-in set for my 141T mainframe for conventional oscilloscope use. I also have a 2 sets of good spectrum analyzer plugins for the 141T for possible barter for the plug-ins I need. I have a 8552B / 8553B combo and a 8552B / 8554B combo.

Dave


Re: HP/Agilent/Keysight version of Tek Wiki?

 

On 1/8/22 1:17 AM, Radu Bogdan Dicher wrote:
Sorry if this was said here or elsewhere, but how does one upload images and/or PDFs to the wiki? I'm trying to build a page (HP5328A), and have original full manuals to scan (work in progress), and also pics to upload, but not sure how. It seems pretty involved from the code-like text on the page when in editing mode.
It's a simple mark-up language whose aim is to be even simpler than HTML, but with increased functionality for certain types of content. This is the point of a wiki.

I've tried to make it even easier by providing a template that users can simply copy to create new pages. The intention behind that was to encourage page-to-page consistency and to provide examples of the constructs in use on the site.

Dokuwiki is one of the simpler wiki systems out there; there's a vast amount of information and help available online for it.

As Chris pointed out, files are uploaded via the upload manager. They are then referenced in your pages.

-Dave

--
Dave McGuire, AK4HZ
New Kensington, PA