开云体育

ctrl + shift + ? for shortcuts
© 2025 开云体育
Date
Re: some 89410A/89441A notes
FWIW, could be old news for many, but I uploaded at ko4bb the required files to enable all software options on a 89410A. The archive is still in the upload area.
By Ovidiu Popa [Business] · #86146 ·
Re: Schematics for HP 8558B SA
Thanks for the quick replies. Today I did find a complete military version of the HP 8558B manual with schematics. I'll start off with this and begin work on the SA, first checking and securing the
By Paul · #86145 ·
Re: Frequency calibration?
Right there with ya.. -Dave [hp_agilent_equipment] wrote: -- Dave McGuire, AK4HZ New Kensington, PA
By Dave McGuire · #86144 ·
some 89410A/89441A notes
Here are some random notes on the expansion options for the 89410A/89441A, for the sake of the archives. Second Channel -------------- It's possible to add the second input channel option
By Dave McGuire · #86143 ·
Re: HP AN/USM 281A Oscilliscope needs repair (San Antonio TX)
One last question for the night. Is there a component failure that would cause the beam/dot not to show on the screen when I apply low voltage to the test leads (1.5v battery) I have to hold the TEST
By Andrew Maich <andremajic@...> · #86142 ·
Re: HP AN/USM 281A Oscilliscope needs repair (San Antonio TX)
Cool. Thank you for the tip on where to check. I'm still trying to figure out if there are any settings I need to try without cracking the case open. I'll save this email for reference when I open it
By Andrew Maich <andremajic@...> · #86141 ·
Re: HP AN/USM 281A Oscilliscope needs repair (San Antonio TX)
Thanks for the help. What can I use for a signal? I don't have a signal generator. I tried testing it with a 3v 800ma wall wart using the EXT INPUT and didn't get a dot or anything. I tried using a
By Andrew Maich <andremajic@...> · #86140 ·
Re: Frequency calibration?
Unless there is a reason for extreme precision in your frequency measuring, you don't need to spend too much money adjusting the oscillator to a reasonable precision. The old method using WWV with a
By Stuart Landau · #86139 ·
Re: [TekScopes] Fast Rise/Fall Time Pulser
Mine arrived today. Alas, it uses a USB B connector instead of a more common USB mini or micro; I gotta get a cable. Mine has the comparator IC marked only, "AJK BAA." Yes, this is an Analog Devices
By Larry McDavid · #86138 ·
Re: Frequency calibration?
What's wrong with my Rubidium reference that would make me choose a GPS disciplined? Costed me $75 on EPay, but still needs a power supply, case and diastribution amplifiers, yet another project to
By Ovidiu Popa [Business] · #86137 ·
Re: Frequency calibration?
I have the same equipment and don't need insane accuracy (1Hz in 100MHz is more the sufficient - 10e-8). I will put the 1PPS signal into the A input, the 10MHz from the ref osc out on the back into
By WA2SCL_Jeff · #86136 ·
Re: Frequency calibration?
They say coffee helps you live longer, I don’t know about how true that is but I do know that it definitely makes me enjoy the time I do have much more! Peter
By Peter Gottlieb · #86135 ·
Re: Frequency calibration?
?????? There are many of us who are slaves to coffee. Have few other bad habits but I can't even talk in the morning before drinking a cup. -- Richard Knoppow dickburk@... WB6KBL
By Richard Knoppow · #86134 ·
Re: Fast Rise/Fall Time Pulser
Yes, works as advertised as far as I can tell. There is plenty of discussion and many screenshots
By Orin Eman · #86133 ·
Re: Frequency calibration?
Two questions for the original poster: How accurate do you need (want) to be? and what are you using the counter for? Time and frequency precision can become an obsession - Time Nuttery. Robert
By Robert G8RPI · #86132 ·
Fast Rise/Fall Time Pulser
There has been discussion recently about generating fast rise/fall time pulses by various means. Here is a link to a Leo Bodnar device that will provide <40 ps rise/fall time, 50% duty cycle, 10 MHz
By Larry McDavid · #86131 ·
Re: Frequency calibration?
Correct! Need more caffeinated beverage. Thanks! [hp_agilent_equipment] <hp_agilent_equipment@...> wrote:
By bownes · #86130 ·
Re: Frequency calibration?
?????? On a standard scope with the same signal on X and Y in phase is a line at 45degrees to the right, 180degrees out of phase is a straight line tilted 45 degrees to the left, a circle is 90
By Richard Knoppow · #86128 ·
Re: VNA design engineer on the list?
Dr. Joel Dunsmore hangs out in the Forums on HP/Agilent/Keysight. [hp_agilent_equipment] <hp_agilent_equipment@...> wrote:
By bownes · #86129 ·
VNA design engineer on the list?
If anyone here designed commercial VNAs, I'd like to call attention to some recent posts I've made to the EEVblog metrology forum on the topic of using an SA and a computer to measure amplitude and
By Reginald Beardsley · #86127 ·