Re: HP8920B power supply removal
Marc, ? Thanks, removing the input assembly is onerous but at least I have a clear path to follow; I feel much more confident now. ? Brian ?
toggle quoted message
Show quoted text
From: [email protected] [mailto:[email protected]] On Behalf Of marcschrdrs Sent: Sunday, November 04, 2018 12:16 PM To: [email protected] Subject: Re: [HP-Agilent-Keysight-equipment] HP8920B power supply removal ? Hi Brian,
never worked on a 8920, but I found a manual which states on p89: Use the following sequence to remove the Power Supply: 1.Remove the Input assembly (see figure 8, "A23 RF Input Assembly," on page 77). 2.Pull the POWER switch shaft forward from the power supply, then pull it out back toward the rear of the Test Set. 3.Remove the screws and molex connector. 4.Slide the power supply out from the bottom of the Test Set.
Good luck, Marc.
|