Hi,
toggle quoted message
Show quoted text
I have repaired a few 3325a synthesizers. I have found that the Sample /Hold switches U20 and U24 have been broken. These are quad devices, only three channels are used in each application. Sometimes swapping them will fix the problem. If you have a manual check service group I The part is an LF13331D. The part is obsolete. A similar, inter-changeable part is used in the 3336 synthesizer/level generators. Good luck !! John Barnes ---------- Original Message ----------------------------------
From: John Day <johnday@...> Reply-To: hp_agilent_equipment@... Date: Tue, 20 Nov 2007 09:15:50 -0500 At 09:02 AM 11/20/2007, you wrote:Hello All,It has been obsolete for some time. ________________________________________________________________ Sent via the WebMail system at aztec-net.com |