¿ªÔÆÌåÓý

Re: 16601


 

On Mon, Oct 1, 2018 at 07:56 PM, Glen Slick wrote:
For the 16600 series you need to go back to version 1.51
as the final version. You probably can't find that anywhere at
Keysight. I have an image of the version 1.51 re-ignite CD if you want
or need to reinstall system software from scratch on a 16600 series.

I can use a copy since I don't have the vers 1.51 re-ignite or any documentation or software.

I've only powered on and looks like no errors and my IBM PS/2 Keyboard and Mouse are working along with the 15" VGA monitor.? ?

I couldn't get the case off easy to clean the inside and inspect to see what the hardware is.??

The system firmware I'm guessing is ISL Revision A.00.38 OCT 26, 1994

Then ISL boots up hpux as noting "ISL booting hpux" and the HP-UX Start-up progress was all OK other than two N/A's from "Start Time Synchronization" and "Start httpd (Web Server)".?

Then the HP Logic Analysis System starts leading to the Windows 95'ish looking OS GUI with a Session Manager screen loading and then a Agilent Logic Analysis System, from 1999 based on the Copyright, splash screen. Then the 16601A Logic Analysis System screen starts showing the E5901A Emulation Module (guessing thats the 16610A) as Slot 1, HP 16601A in Slot A and HP 16533A in Slot B.??

I didn't connect anything to run yet since I need to read into and acquire a POD set.? Looks like there is a Demo Center and Help section installed, so I can start there since I have no documentation relating to.?

I was originally thinking I'd replace the P-ATA drive with a P-ATA SSD drive, though looks like the primary boot path is: SESCSI.6.0 with an alternate boot path: SESCSI.1.0.?

So I'm thinking this is a SCSI drive system and I've not swapped SCSI drives with an SSD yet.? Would swapping the drive using an adapter even be plug and play capable since there aren't SCSI SSD drives that I am aware of???

Thanks for the feedback.??

?

?

?

??

Join [email protected] to automatically receive all group messages.