lothar baier
you are talking about the 8444 not the 8443, the 8443 actually does not require a 500MHz signal
toggle quoted message
Show quoted text
Alan Melia <Alan.Melia@...> wrote: Hi, just a though triggered by Chuck's posting. Some of the connectors for the tracking gen were fitted as an "update" I think (without looking at my frame) there is another cable inside from the back of the frame and the plug-in bay. So there are a lot of connectors in series. It would only take one of the 2 or 3 cables/conns from the LOs to the TG to be open for the Tg to produce no output. I hesitate on this because without checking the manual I am not sure whether you would get a marker in that state. Another though but I dont remember whether it refers to this unit is that some RF heads dont output the third LO with is 500MHz and this must be generated locally in the TG . failure of this unit there would mean no output too. You dont say whether you have measurable output from the TG (scope??) and whether it is actually on the right frequency (I would imaginne the output goes via a 100MHz LPF so one osc off and no signal). Separate test equipment is better than trying to define the problem all in the same two units. Alan G3NYK ----- Original Message -----
From: "Chuck Harris" <cfharris@...> To: <hp_agilent_equipment@...> Sent: Friday, November 16, 2007 2:41 PM Subject: Re: [hp_agilent_equipment] Re: HP-8443A Tracking Generator Problems One very big problem with the 141T frame and its plug-ins, that can causeplug-in. The aluminum framework that holds these D style connectors is too thin andresults in a partially working SA. --------------------------------- Get easy, one-click access to your favorites. Make Yahoo! your homepage. |