One of those tiny cheap $50 VNA would do the job as well.? And if
a guy does very much RF work at all, a VNA is a **exceptionally**
handy gadget to have laying around.?
73/jeff/ac0c
alpha-charlie-zero-charlie
On 1/24/2024 4:15 PM, si_emi_01 via
groups.io wrote:
toggle quoted message
Show quoted text
An
HP-4192A or HP-4191A will do that with ease.
?
The
HP-4192A will go up to 13MHz, but you need the right test
fixture. The test fixture interface is through 4 each BNC
connectors that become either Balanced (Signal Source High
and Low to Sense High and Low - Kelvin really), and
Unbalanced High and Low tied at a High and Low Contact in
the fixture.
?
The
HP-4191A might be better as it starts at 1MHz and will go up
to 1GHz with the proper fixturing. The HP-4191A has a much
higher Frequency Interface (Coaxial RF), to the test
fixtures (an APC-7), so more accurate readings are possible.
?
Ross
?
?
?
?
I have a
bridge that might fit the bill I will look and see what the
frequency response is, also how large an inductor? The
larger the inductor the more difficult this will be.
?
Zen
?
From: [email protected]
<[email protected]>
On Behalf Of Maciej Kawalkowski, Liberty
Electronics Design and Service LLC
Sent: Wednesday, January 24, 2024 2:19 PM
To: [email protected]
Subject: [HP-Agilent-Keysight-equipment] Looking
for someone with 1MHZ capable LCR in the Cincinnati area
?
I need to measure so inductor properties
and my LCR only goes to 100kHz . Anyone in the Cincinnati Area
have a meter I can use up to 1Mhz or I can send parts for
measurements.??