What is interesting to me is the expectation of greater accuracy than was possible. Essentially, the display LEDs on an 8350B are part of a Voltmeter, not a FREQUENCY COUNTER. 5 MHz at 10 GHz is .05% accuracy: Pretty impressive for something designed 40+ years ago...
Non synthesized sources!
Jeff Kruth
In a message dated 11/19/2023 12:34:12 PM Eastern Standard Time, yves_tardif@... writes: ?
Martin, ? You wrote: "The microwave module is even worse, at 10GHz its off by 5MHz with no CAL as the other modules have." The frequency accuracy maybe off by 5MHz, in CW mode, the tolerance is ¡À20MHz. ? The FREQ CAL potentiometer on the front panel is only used to align a cavity oscillator for down conversion to cover a frequency band starting at 10 MHz. Your 83545A covers a range of 5.9-12.4GHz, so this FREQ CAL control will be missing. ? ? ? The DIP switch can be modified to configure certain parameters. Here is the list for each switch. Switch #2 and #3 do not show details, but for the 83540A, switch 2 is at 1, and switch#3 is at 0. ? ? De?: [email protected] <[email protected]> De la part de Martin via groups.io ? Hi Yves, ? |