Re: 3458A Schaffner Mains Filter


 

¿ªÔÆÌåÓý

As far as I know there is not a problem. We've fitted hundreds of assorted types of Schaffner IEC input filters to equipment since the mid 1990s and as far as I know without any failure. I suppose there may have been failures but our customers may just not have mentioned it to us? (Unlikely!)

It is true that most of those will have been living in 220/240VAC land their whole lives whereas the only HP fitted one I've had fail went within a day or so of crossing the Atlantic and seeing 240V for the first time.

Any 'stand alone' yellow Rifa caps you find serving as input filters should be changed with extreme prejudice on sight however!?

On 06/09/2022 09:30, Stephen Bell wrote:

I have recently acquired a 3458A which incorporates a Schaffner FN9223-3-06 mains filter. The 3458A has a build date of approx 2005 and the Schaffner filter has a date code of 0432.

I am wondering if these later Schaffner filters have the same dramatic failure mode exhibited by their earlier models and whether it should be replaced. I am reluctant to replace it if it is not necessary due to it being riveted into the chassis.