¿ªÔÆÌåÓý

Re: HP200CD oscillator


 

¿ªÔÆÌåÓý

Richard,

The voltage at the R40/31/30 junction should be in the order of -180VDC with respect to the chassis. Note that this is the negative bias voltage generated across R40.

If your voltage is +132V at R40/31/30 you have big troubles ¨C maybe check again to see if it is in fact negative.

Next check the voltages at the cathodes of V2 and V4 these should be in the vicinity of -3.6VDC ¨C mine are -3.2 and -2.8 and the generator works OK. This is pin 3 on V2 and 4.

Also check the grids of V2 and 4. Pin 2, ?and these should be around -19.5 or some such. Again mine are different at -16.5 and -16.7.

Another check is to monitor the voltage at the junction of R40/31/30 whilst changing the Range switch from x100 to x 10K. there should be very little if any change. This checks to see if there are any issues with the two output transformers.

One more thing ¨C on almost every 200CD that I have see C12 100uF NON POLARISED has gone bad. As we are only looking at the DV characteristics at present disconnect C12 9accross C30/31) and see if there are any changes to the DC bias voltages.

?

Good luck

Mark

?

?

From: [email protected] <[email protected]> On Behalf Of Richard Merifield via groups.io
Sent: Sunday, 7 November 2021 8:44 PM
To: [email protected]
Subject: Re: [HP-Agilent-Keysight-equipment] HP200CD oscillator

?

I repaired L2 as best I could and it measured ok so thought I would give it a try. I suspect on 6AU6 may be part of my problem. I swapped them around and I now have a perfectly functional unit as far as I can tell, except R30 gets scolding hot still. I have 4 more 6AU6 coming.

I measured the voltage at the R40/R31/R30 junction at 132V DC and -5.8V and -5.3V on the other side of R30 and R31 respectively with respect to chassis ground. Why would R30 get twice as hot as R31 given those measurements? Don't they effectively have almost the same current flowing across them ? I desoldered R30 and it measure 3.1kOhm but perhaps something else is wrong with it ?

I think I am getting closer

Regards

Richard

Join [email protected] to automatically receive all group messages.