From my notes: almost a quarter of a century ago I had a similar failure. Just replaced the power diodes (3A) and all went fine. The A/B23 go to SS 23: the -5.2 V regulator. Let me know if you need more info.
Good luck, 73 de
Harke
On Friday, April 17, 2020, 12:41:20 PM GMT+2, Armin Roesch <armin.roesch@...> wrote:
Main Fuse blown. Fuse replaced >> ON >> generator shows frequency and level correct. After 10 seconds smells very strange. >> OFF It smells that C6 22nf (parallel main filter output) became faulty. >> Removed >> ON All voltages seems to be correct. >> Then smoke from the rectifier board >> OFF Remove rectifier board. CR17 fall of the board! CR20 looks like it was very hot No idea where output A/B 23 is for? Did not found the goal of that voltage. Any idea? Thanks for hints. Armin HB9MFL