Re: HP8562A Errors 304,335,317,333


 

¿ªÔÆÌåÓý

Hello Stu thie MMIC is placed on the A15 board the is the lowest on the analyzer. It is below the screens on the PCB. I will look dokumentation if I still can find it.
Any MMIC can do it if it can make around 20dBm
best regards Peter


Fra: [email protected] <[email protected]> p? vegne af stur_mm via groups.io <stuart.ian.richardson@...>
Sendt: 16. april 2020 17:33
Til: [email protected] <[email protected]>
Emne: Re: [HP-Agilent-Keysight-equipment] HP8562A Errors 304,335,317,333
?

Peter,

?

Which board are we talking about ?

Still looking for the LED PSU indicators on the A2 card.

?

Presume you are referring RF board..?

Is this an off the shelf part or HP proprietary?

?

Thanks,

?

Stu.

?

From: [email protected] <[email protected]> On Behalf Of Peter Hansen
Sent: 16 April 2020 06:59
To: [email protected]
Subject: Re: [HP-Agilent-Keysight-equipment] HP8562A Errors 304,335,317,333

?

Hello Group a TAM is not needed in this case. It is simply a MMIC in the 300/600Mhz chain that is bad.

I believe Harke has a Hp85629A TAM for sale.

best regards Peter Hansen

?


Fra: [email protected] <[email protected]> p? vegne af Don Bitters via groups.io <donbitters@...>
Sendt: 16. april 2020 06:58
Til: [email protected] <[email protected]>
Emne: Re: [HP-Agilent-Keysight-equipment] HP8562A Errors 304,335,317,333

?

I suspect you might be able to rent the TAM from one of the ETE rental outfits for a month or so for not a horrible price.? I believe that Tam Hanna has one or two for sale, I may purchase one from him for my own use with my 8562A.
Don Bitters


Join [email protected] to automatically receive all group messages.