¿ªÔÆÌåÓýThanks for all the replies, ? further poking hasn't revealed much yet, though I haven't completely ruled out the front end connector yet (seems solid though). Power supplies seem ok. ? I'm slightly suspicious of the sampler driver at this point. It occurs to me that if somehow that were damaged in a way that suppressed even harmonics (idk how that could occur yet though) this seems like the symptoms that I'd expect to see. ? Further troubleshooting of that is on hold while I fix my 8555A, which apparently decided now was the perfect time to lose its +10V and +20V power supply:( But once that's fixed I'll come back to this. ? Best, Daniel ? ? From: <[email protected]> on behalf of Askild <megafluffy@...> ? Hi Daniel, ? Check the power lines for ripple. I have a HP 5351B dumpster find, that did not work to well, needed higher input level, and did not work on all frequencies... It was missing one of the capacitors in the power supply, so lots of ripple. After finding the missing cap, and putting in a new one, it behaved great. ? Might not be your issue, but its an easy check.. ? BR, Askild ? ? On Fri, Apr 10, 2020 at 7:49 PM Daniel Sheen <danielsheen5@...> wrote:
|