Re: 8350B w/83590A repair advice


 

Hi Chuck
That reminds me
I must order some new cells as all of my 8350 are running without any
batteries

Ok winter job I have collected a truck load of 8620 10 off
so must service and make good should salvage 8 out of the 10

Regards Paul

-----Original Message-----
From: [email protected]
[mailto:[email protected]] On Behalf Of Chuck Harris
Sent: 14 December 2019 15:45
To: [email protected]
Subject: Re: [HP-Agilent-Keysight-equipment] 8350B w/83590A repair advice

Note that the 8350B has a 3- AA cell nicad battery,
repurposed from the HP-35 calculators. The pack is
on trickle charge whenever the 8350B is turned on,
and after a year, or two of that abuse, spews its
highly caustic guts all over the side of whatever
plugin is in the 8350B at the time.

The electrolyte tends to ruin the GPIB board, and
the plugin's main circuit board.

You might look there.

-Chuck Harris

pa0jme1952@... wrote:
I took a look at the blockdiagram of my 83592, which differs only with an
extra low band mixer,
The sweeper unit is a cascade of
a) YTO o/p 2.4-7.0GHz
b) amplifier
c) isolator
d) YTM (multiplier)
e) YTF
The most probable cause imho is tracking of the 3 YIG devices, at least
that's my experience with the older 86290B which showed the same symptoms.
The tracking is done by opamp controlled current sources and can be caused
by resistor ageing
Unfortunately I gave a few years ago my 83590 manuals away
Best regards Rien








-----
No virus found in this message.
Checked by AVG - www.avg.com
Version: 2016.0.8048 / Virus Database: 4793/15886 - Release Date: 08/14/18
Internal Virus Database is out of date.