Hi Chuck
toggle quoted message
Show quoted text
That reminds me I must order some new cells as all of my 8350 are running without any batteries Ok winter job I have collected a truck load of 8620 10 off so must service and make good should salvage 8 out of the 10 Regards Paul -----Original Message-----
From: [email protected] [mailto:[email protected]] On Behalf Of Chuck Harris Sent: 14 December 2019 15:45 To: [email protected] Subject: Re: [HP-Agilent-Keysight-equipment] 8350B w/83590A repair advice Note that the 8350B has a 3- AA cell nicad battery, repurposed from the HP-35 calculators. The pack is on trickle charge whenever the 8350B is turned on, and after a year, or two of that abuse, spews its highly caustic guts all over the side of whatever plugin is in the 8350B at the time. The electrolyte tends to ruin the GPIB board, and the plugin's main circuit board. You might look there. -Chuck Harris pa0jme1952@... wrote: I took a look at the blockdiagram of my 83592, which differs only with anextra low band mixer, The sweeper unit is a cascade ofthat's my experience with the older 86290B which showed the same symptoms. The tracking is done by opamp controlled current sources and can be causedby resistor ageing Unfortunately I gave a few years ago my 83590 manuals away ----- No virus found in this message. Checked by AVG - www.avg.com Version: 2016.0.8048 / Virus Database: 4793/15886 - Release Date: 08/14/18 Internal Virus Database is out of date. |