problem meet when run dfsmsdss restore
hi all, i have built?4.6.0.10941-SDL-g65c97fd6 on?Linux-5.14.0-284.25.1.el9_2.x86_64. the hercules runs well. and i built an standalone ickdsf to initialize the cckd volume. INIT UNITADDRESS(52C1)
By shixinlong@... · #4336 ·
Re: Hercules Error Messages Undocumented??
Please post your config file for both instances of hercules ... the one on the MAC and the one on Windows. Joe
By Joe Monk · #4335 ·
Re: COBOL Sort - - +IER040A - INSUFFICIENT WORK UNITS
Excellent. Thanks. Sent: Friday, March 1, 2024 7:43 PM To: [email protected] Subject: Re: [H390-MVS] COBOL Sort - - +IER040A - INSUFFICIENT WORK UNITS Hi Guys, My suggestion is that if you
By Mike Ward · #4334 ·
Re: COBOL Sort - - +IER040A - INSUFFICIENT WORK UNITS
Hi Guys, My suggestion is that if you have migrated to TK5 then take advantage of the enhancements with OS/360 Sort/Merge for MVS 3.8. Just delete all SORTWKxx DD statements in sorting steps, COBOL
By Tom Armstrong · #4331 ·
Re: Cross Memory Address space data exchange/communication
The classic way a lot of program products flagged their presence was to add their own subsystem to the SSCT (SSCVT?) chain.? They offered no subsystem services as such but used the SSCT (via the
By Greg Price · #4330 ·
Re: Cross Memory Address space data exchange/communication
Dear Bob, Mark, Dennis, Jo?o, Silvio and Wally, I'm simply overwhelmed by the number of responses on my initial post and the pointers in various directions. Lot's of ideas to delve deeper into as
By Michael Grom · #4329 ·
Re: COBOL Sort - - +IER040A - INSUFFICIENT WORK UNITS
Frank, if you enter /d u on the hercules montor, you will see:- 130 2314 OFFLINE 131 2314 OFFLINE 132 2314 OFFLINE 133 2314 OFFLINE 134 2314 OFFLINE
By cjar1950@... · #4328 ·
Re: Cross Memory Address space data exchange/communication
Hi Wally and Silvio, In NJE38's case, the ENQ is not used for serialization at all.? No other ENQs are issues by any NJE38 component.? Rather, the ENQ's purpose is simply to place a QCB entry into
By Bob Polmanter · #4327 ·
Re: COBOL Sort - - +IER040A - INSUFFICIENT WORK UNITS
Do you happen to know what CUUs are defined for 2314 in TK5? I did add 2314s to my config and was able to create VTOCs on them but they are not mounting. Even if they are no longer required I would
By Frank D. Engel, Jr. · #4326 ·
Re: Cross Memory Address space data exchange/communication
The ENQ/DEQ is not to serialize the request but to save the CSA ECB address in the RNAME. You need it in order to use the cross memory POST/WAIT. In z/OS V2 you can use a TOKEN instead of ENQ/DEQ to
By Jo?o Reginato · #4325 ·
Re: COBOL Sort - - +IER040A - INSUFFICIENT WORK UNITS
The problem is the UNIT=2314 in the JCL.? The sort/merge utility in TK5 works with any DASD.? Try UNIT=SYSDA in your jcl since TK5 does not have 2311 or 2314 volumes defined in the Hercules config
By Ed Liss · #4324 ·
Re: Cross Memory Address space data exchange/communication
Dear all, I did multiple implementations of Cross memory communications. To give some concrete idea how to bring the very good theory from the posts in this area here in the group, I include a txt
By Silvio Losa · #4323 ·
Re: Cross Memory Address space data exchange/communication
Instead of using ENQ a better way to is to use 2 different ECBs. The caller POSTs the first one and then WAITs on the second. The request processor just does the opposite. Wally Sent:
By Wally Mclaughlin · #4322 ·
Re: Cross Memory Address space data exchange/communication
Hi all, I just wanted to add a little to this conversation. Another way to pass the address of the CSA area is to utilize the CVTUSER field in the CVT. We did this at a former job. We would allocate
By Dennis Stone · #4321 ·
Re: Cross Memory Address space data exchange/communication
Hi Michael, To follow on with what Mark posted, there are other ways to perform cross-memory (XM) communication that do not need SRBs.? Everything Mark posted is correct.? But there are easier
By Bob Polmanter · #4320 ·
Re: COBOL Sort - - +IER040A - INSUFFICIENT WORK UNITS
Hi I read Jay Moseley's FAQ about the cobol sort utility so that is why I was pre-allocating the files. When reading the cobol -74 manual I was able to sort out that it was not needed. The program
By Dagfinn Hammar · #4319 ·
Re: COBOL Sort - - +IER040A - INSUFFICIENT WORK UNITS
Dagfinn, What is the purpose of the GO.SORTDD statement? You are allocating a new data set ¨C but did NOT specify a volume serial Also, you should NOT need a COB.SYSLIB ¨C this would be input to the
By Jeff Bassett · #4318 ·
Re: COBOL Sort - - +IER040A - INSUFFICIENT WORK UNITS
Frank You can look at SYS1.SYSGEN.SOURCE(IOGEN) On MY TK5 here is what I see //* DASD devices //* //* ! Devt ! Cua - Cua ! Cua - Cua ! Cua - Cua ! Cua - Cua ! Cua - Cua ! //*
By Jeff Bassett · #4317 ·
Re: COBOL Sort - - +IER040A - INSUFFICIENT WORK UNITS
The issue is the OLDER Sort Merge ¨C did not support the newer DASD and Dynamic allocation When the TK5 was built ¨C the newer product was installed and will now no longer require 2311 and 2314 And
By Jeff Bassett · #4316 ·
Re: COBOL Sort - - +IER040A - INSUFFICIENT WORK UNITS
Yes, the DASD are listed in the Hercules config file as well as (since I am running under VM) the VM directory for the MVS virtual machine. No problems there as the ICKDSF worked; I can also see them
By Frank D. Engel, Jr. · #4315 ·