Re: Looking for a dataset
https://github.com/SDL-Hercules-390/hyperion/blob/master/readme/README.TCPIP.md --- ¦Ó¦Òm
By botongrui, aka ¦Ó¦Òm. · #4275 ·
Re: Looking for a dataset
Hi, Where can I find the TCPIP readme document? Cheers, Rob
By Rob Prins · #4274 ·
Re: Looking for a dataset
Thank you Sir. It is appreciated.
By Mike Ward · #4273 ·
Re: Looking for a dataset
That dataset was mentioned in the TCPIP readme, but never made it into the TK4- distribution. I asked about it over on the Turnkey-MVS list a while ago and Shelby provided
By Matthew Wilson · #4272 ·
Looking for a dataset
Hello all, I'm looking for a specific dataset that I am unable to find. The dataset is: TK4-.SHELBY.EZASMI.V100.ZIP I have done an IEHLIST of all the volumes on the TK4- that I have installed and I
By Mike Ward · #4271 ·
Re: Help needed to write test data to 3390 track
Anders Edlund wrote: Neither do I (I'm not an MVS/zOS person), but it sounds like it *might* be a problem. Should not be touched at all? Why? I don't understand. :( I believe a simple Hercules
By Fish Fish · #4270 ·
Re: Help needed to write test data to 3390 track
Yes IEBDG can write what you are looking for, but I guess that running it under any OS would also write an EOF record after the last 4kblock. How that would affect the test, I do not know, but after
By andersedlund@... · #4269 ·
Re: Help needed to write test data to 3390 track
Hi Fish, This can be done with IEBDG. See the job below: / /Z531415A JOB (ACCNT),'IEBDG',CLASS=A,MSGCLASS=X,NOTIFY=&SYSUID //* //GEN????? EXEC? PGM=IEBDG //SYSPRINT DD? SYSOUT=* //GENOUT1?
By Rob Prins · #4268 ·
Re: Help needed to write test data to 3390 track
(Oops!) Sorry about the blank subject line, folks!
By Fish Fish · #4267 ·
Re: DLI loading on Tk4 and MVSCE?
John James wrote: * https://sdl-hercules-390.github.io/html/hercinst.html#HAO So, e.g.: hao tgt IEA101A... hao cmd /r 00,clpa hao tgt ...(clpa response message)... hao clear (I don't
By Fish Fish · #4264 ·
Re: DLI loading on Tk4 and MVSCE?
Just wondering how to persuade the automated operator to do it for me. As a fully paid-up member of the Lazy so-and-so society, JJ
By John James · #4263 ·
Re: DLI loading on Tk4 and MVSCE?
JJ, Yes, you can do that, simply reply R 00,CLPA should work. Wally Sent: Wednesday, February 14, 2024 03:44 PM To: [email protected] Subject: Re: [H390-MVS] DLI loading on Tk4 and
By Wally Mclaughlin · #4262 ·
Re: DLI loading on Tk4 and MVSCE?
Hello Wally, thanks for the information. An alternative strategy I was thinking about was to CLPA at every IPL anyway - what harm could it do? Forgive my lack of knowledge about the automated
By John James · #4261 ·
Re: CURRENT-DATE and TIME in cobol MVS 3.8 - time is shown as HHMMSS. I use PIC 9(8). Result is as follows: DATE : 02/14/2
You cant get milliseconds. In MVT cobol, you get HHMMSS. [image: image.png] Joe wrote:
By Joe Monk · #4260 ·
Re: CURRENT-DATE and TIME in cobol MVS 3.8 - time is shown as HHMMSS. I use PIC 9(8). Result is as follows: DATE : 02/14/2
Try PIC X(8). Sent from my iPad Air 2
By Don.isenstadt · #4259 ·
CURRENT-DATE and TIME in cobol MVS 3.8 - time is shown as HHMMSS. I use PIC 9(8). Result is as follows: DATE : 02/14/2
Hi I use the current-date and time function in cobol. I am able to get the correct syntax for current-date but struggle to get the time to get milliseconds from this function. Any suggestions on how I
By Dagfinn Hammar · #4258 ·
Re: Reorganizing a user catalog in MVS.
MVS has the Pre-ICF catalog with those limits. alejandro.olivan.alvarez@...> wrote: -- Mike A Schwab, Springfield IL USA Where do Forest Rangers go to get away from it all?
By Mike Schwab · #4257 ·
Re: Reorganizing a user catalog in MVS.
Hi again folks. I'm having issues with catalog 'dumps' resulting from REPRO. While they look good, I can't use them: I have re-read Jay's doc and I've acknowledge that DASD volumes do have or belng
By Alejandro olivan Alvarez · #4256 ·
Re: Unattended/Scheduled backups ideas.
Sure! I hope it doesn't get too wordy. First, I run IDCAMS to list all catalogs, master and user. I create all tapes with a HLQ of TAPE, but I check all catalogs just in case. Then I wrote a program
By Dennis Stone · #4255 ·
Re: Unattended/Scheduled backups ideas.
Hi all guys! Sure... this thread is the consequence of me struggling with the catalog 'expertise' :-P ... my troubles do 'fork' as I trip wires left and right while trying to go somewhere :-) So, at
By Alejandro olivan Alvarez · #4254 ·