I missed part of this.? Yes, it¡¯s MVS, the tk5, update 2 distribution.
toggle quoted message
Show quoted text
Scott Johnson wrote:
> Recently, when saving a member to a PDS I've been getting
> this message:
>
> SCOTT? ?,ISPFTSO ,294,DA,SYS00083,WRITE ,OVERFLOW
> INCOMP,0000000A000A02,BSAM
That's an MVS message, yes? Does anything also appear on the Hercules console when this error message? If yes, then it's a bona fide I/O error.
Second question: is it reproducible? Is there a sequence of actions that can trigger this error on demand? If yes, then I would suggest enabling CCW tracing on device 294, so we can the CCW chain that MVS is issuing. That would provide a clue as to what's going on.
May we see your Hercules log when this error occurs? Seeing your config file might also help.
Thanks.
--
"Fish" (David B. Trout)
Software Development Laboratories
mail: fish@...