Re: revisiting SYSGEN in Z world
Mike; I think it will default to my old system catalog not to the one I created on the empty volume SY2KB. IEF376I? JOB/TWO$70? /STOP? 2020333.1151 CPU??? 0MIN 00.16SEC SRB??? 0MIN 00.02S IDCAMS? SYSTEM SERVICES?????????????????????????????????????????? TIME: 11:51:11?????????????????????????????????????????????????????????????????????????????? ? ??????????????????????????????????????????????????????????????????????? 00008300 ? EXPORT SYS1.VSAM.MASTER.CATALOG DISCONNECT??????????????????????????? 00008400 IDC3012I ENTRY SYS1.VSAM.MASTER.CATALOG NOT FOUND????????????????????????????? ? IDC3009I ** VSAM CATALOG RETURN CODE IS 8 - REASON CODE IS IGG0CLEG-42???????? ? IDC3003I FUNCTION TERMINATED. CONDITION CODE IS 12???????????????????????????? ? ?????????????????????????????????????????????????????????????????????????????? ? ??????????????????????????????????????????????????????????????????????? 00008500 ? SET LASTCC = 0??????????????????????????????????????????????????????? 00008600 ?????????????????????????????????????????????????????????????????????????????? ? ? SET? MAXCC = 0??????????????????????????????????????????????????????? 00008700 ?????????????????????????????????????????????????????????????????????????????? ? ??????????????????????????????????????????????????????????????????????? 00008800 ? DEFINE USERCATALOG (???????????????? -??????????????????????????????? 00008900 ?????????????? NAME(SYS1.VSAM.MASTER.CATALOG) -???????????????????????? 00009000 ?????????????? FILE(SYSUT1)??????????? -??????????????????????????????? 00009100 ?????????????? VOLUME(SY2PKB)????????? -??????????????????????????????? 00009200 ?????????????? CYLINDERS(30)?????????? -??????????????????????????????? 00009300 ?????????????? BUFFERSPACE(8192) )????????????????????????????????????? 00009400 IDC0510I CATALOG ALLOCATION STATUS FOR VOLUME SY2PKB IS 0????????????????????? ? IDC0512I NAME GENERATED-(I) SYS1.VSAM.MASTER.CATALOG.CATINDEX????????????????? ? IDC0001I FUNCTION COMPLETED, HIGHEST CONDITION CODE WAS 0????????????????????? ? ?????????????????????????????????????????????????????????????????????????????? ? ??????????????????????????????????????????????????????????????????????? 00009500 IDC0002I IDCAMS PROCESSING COMPLETE. MAXIMUM CONDITION CODE WAS 0?????????????? regards; Rahim ?? ??
On Saturday, November 28, 2020, 6:28:40 PM CST, Mike Schwab <mike.a.schwab@...> wrote:
Not needed.? If you didn't created a matching alias the default is the master catalog. On Sat, Nov 28, 2020 at 6:05 PM Rahim Azizarab via groups.io
<rahimazizarab=[email protected]> wrote: > > I ran the JCL to create an IPL volume and it went flawlessly.? Then I created my Master catalog which went fine too; but when it came time to allocate my system datasets (SYS1) under my newly created master catalog Zos does not allow STEPCAT or JOBCAT to catalog my system files under my newly created catalog.? This is when the old MVS38 comes handy because I can move my DASD to MVS38 and allocate my SYS1 datasets under my Master Catalog then I can bring it back to add contents to them. > >? ? ? ? ? //* >? ? ? ? 11 //RECATLG? EXEC PGM=IDCAMS,REGION=1024K,COND=(0,NE,DEFCAT) >? ? ? ? ? //* >? ? ? ? ? //* CATALOG SMP DATASETS >? ? ? ? ? //* >? ? ? ? 12 //STEPCAT? DD? DSN=SYS1.VSAM.MASTER.CATALOG,DISP=SHR >? ? ? ? 13 //SYSPRINT DD? SYSOUT=* >? ? ? ? 14 //SYSIN? ? DD? * >? ? ? ? ? //*? ? ? ? END OF SUBMITTED SYSGEN00 (2 OF 2) >? ? ? ? 15 //SYSIN? ? DD *? ? ? ? ? ? ? GENERATED STATEMENT >? ? ? ? 16 //SYSUT2? DD? SYSOUT=(A,INTRDR) >? ? ? ? ? //*? ? ? ? END OF PRIMARY SYSGEN00 >? STMT NO. MESSAGE >? ? ? ? 7 IEFC034I JOBCAT OR STEPCAT NOT PERMITTED >? ? ? ? 12 IEFC034I JOBCAT OR STEPCAT NOT PERMITTED > > > > Rahim > > > > > > > > > -- Mike A Schwab, Springfield IL USA Where do Forest Rangers go to get away from it all? |
to navigate to use esc to dismiss