When you want to stop MVS and Hercules do you do a complete shutdown of MVS and issue the QUIESCE command as the last thing you do on the MVS console? This command puts MVS in a wait state after all pending I/O is processed. It is possible that than some paging may be going on.
Laddie Hanus
Sent from whatever device I am using.
toggle quoted message
Show quoted text
On Sep 8, 2020, at 7:03 PM, lbelmontes@... wrote:
?Over the past few months, I've noticed page file errors becoming more prevalent on my?MVS38J TK3 system.? Sometimes when the system has been running for 1 day and others when running for about 7 days before IPLing.
The system is mostly idle.? Nightly backups and compile/assembly throughout the day.
The error messages are:
*ILR009E LOCAL? PAGE DATA SET ON VOL PAGE02 BAD
*ILR009E LOCAL? PAGE DATA SET ON VOL PAGE00 BAD
I've read some emails from the archives suggesting copying the PAGExx DASD file from the TK3 distribution CD to correct the problem...
However, I wanted to solicit some feedback from the experts on this forum.?
What is the root cause???? A bad DASD file???? Any diagnostics I can perform?? Any pointers to manuals??
Thanks in advance!? Any feedback will be appreciated.
Larry Belmontes