There is no mode in which using Vista 3270 as the master console works without causing a superdump in the early stages of IPL of MTS when running Hercules 4.x.?
Note, this is not the case for Hercules 3.x (3.06, 3.13). They don't exhibit this behavior.
I will see about opening a ticket in order to help diagnose the problem.
John
toggle quoted message
Show quoted text
On Mon, Sep 18, 2023 at 01:00 AM, Fish Fish wrote:
(*) If I'm understanding things correctly, the problem stems from your connecting a non-standard 3270 model-2 (24x80) device to MTS's "master console", yes? That if you define your Vista 3270 terminal as a normal model-2 (24x80) 3270 device, then it works fine, yes? That the problem only occurs when you connect your Vista 3270 to MTS's master console address as a 3279 model-5 (132x80) device, then the problem occurs, yes? If that's the case (if what I said is true), then that would be classified as PEBKAC IMO.
If that's NOT the case however (if what I wrote above is wrong), then I would appreciate your help with debugging this.
Thanks.
--
"Fish" (David B. Trout)
Software Development Laboratories
mail: fish@...