Hi Daniel,
I may have missed it, what version of Gemini are you using and what firmware?
Since you seem to have a problem with the mount being powered on for 48+ hours, can you power it down and then warm (re)start the next time, not leaving it on?
Regards,
? ? -Paul
toggle quoted message
Show quoted text
On Sat, Mar 12, 2022 at 01:51 AM, Daniel Judge wrote:
This one still seems to reoccur and I can't see why. Is there a limit to the number of sync positions held in the formation of the pointing model? Is there a saved value for the home positon/park position?
I'm not sure if constant platesolve and sync from the software is overloading the sync points the gemini is using/saving with the model.
The only fix is to position the mount to CWD, power the mount off, reconned and cold start from cwd, create a pointing model again and continue. Rinse and repeat.