Re: G2 logs access
Hi Art, if you use the ASCOM driver virtual hand controller, you can go to the Setup->Troubleshooting Report... option while your Gemini is connected to the PC. Select all options, and press Collect
By Paul Kanevsky · #28553 ·
Re: Gemini BOOTLOADER update available
Hi Dave, no, the JTAG/ULINK2 unit is just for Bootloader update (can also be used to program and debug the ARM CPU, should you feel the need to ;)) What I think you're referring to is the upgrade to
By Paul Kanevsky · #28552 ·
Re: Gemini BOOTLOADER update available
Hi David, those files are not needed when using Keil debugger to flash the bootloader.
By Paul Kanevsky · #28551 ·
Re: Gemini BOOTLOADER update available
Will this same hardware (the Amazon thingy)/software(Keil) update accomplish the upgrade from not 6 to 6 level firmware? Dave
By David Wormuth · #28550 ·
Re: Gemini BOOTLOADER update available
Paul I think that the Objects sub-folder should also contain files: BL_Gem2.bin, and MB_BL_2024.hex? D. Sent: 11 April 2025 12:34 To: [email protected] Subject: Re: [Gemini-II_io] Gemini BOOTLOADER
By David C. Partridge · #28549 ·
G2 logs access
Hello all, where can I find the G2 logs? I am troubleshooting a "disconnect" problem (per ASCOM logs). Not sure if it actually is an ethernet problem or the mount just simply "checking out". I feel
By Art Trail · #28548 ·
Re: Gemini BOOTLOADER update available
Good news! Thanks for reporting the issue and then testing the update, Don! It makes sense, but it is an unanticipated benefit that faster booting means that GFU is no longer required to wait minutes
By Paul Kanevsky · #28547 ·
Re: Gemini BOOTLOADER update available
Hi Paul, Great news! ?This new file worked perfectly. ?Attached is a photo of the final confirmation. Also, and this is the best part, no more timeout error messages when updating via the GFU! ?I
By Don Klase · #28546 ·
Re: Gemini-2 confusing east and west
Paul, thanks for the suggestion.? I checked the mount last night and the problem didn't happen after almost a week being off; it seems like the firmware update (and/or the new battery) may have fixed
By Joe Ulowetz · #28545 ·
Re: Gemini BOOTLOADER update available
Hi Don, and others, Please try this file ( /g/Gemini-II/files/Latest%20Firmware%20Files/Bootloader%20Update%20Instructions%20-%20April%202025/BL24upload.zip ) instead of the .uvproj
Re: Mount Disconnect and Ignores Safety Limit
On Thu, Apr 10, 2025 at 09:38 PM, Konstantin Baranov wrote: > > 1. I was told the problem is that some SD cards are 2GB when they should > be 8GB. I don't know more details how exactly is causes
By Paul Kanevsky · #28543 ·
Re: Mount Disconnect and Ignores Safety Limit
1. I was told the problem is that some SD cards are 2GB when they should be 8GB. I don't know more details how exactly is causes problems... Are there known issues around that? I am in Las Vegas, NV.
By Konstantin Baranov · #28542 ·
Re: Mount Disconnect and Ignores Safety Limit
Hi Konstantin, There are many symptoms that you're describing that are hard to diagnose individually, but taken alltogether might be even harder to explain :) Let me try to put my thoughts down, one
By Paul Kanevsky · #28541 ·
Re: Gemini BOOTLOADER update available
Ah ok I¡¯ll wait for further instructions. Thanks for your help!
By Don Klase · #28540 ·
Re: Gemini BOOTLOADER update available
In step 2, looks like the ARM compiler version 5 is missing.
By Don Klase · #28539 ·
Re: Gemini BOOTLOADER update available
Yes, there are a few files missing that should be included. The full bootloader was a compressed zip file with this project file and some additional files under the Objects folder. I asked Ren¨¦ to
Re: Gemini BOOTLOADER update available
I was caught cross posting whips you were posting. Bbad internet juju! cheers -- Brendan
By Brendan · #28537 ·
Re: Gemini BOOTLOADER update available
Bren, I think you're right. The project file that Losmandy made available is just part of the package and is missing some extra files.
By Paul Kanevsky · #28536 ·
Re: Gemini BOOTLOADER update available
Hi Don i looked at old boot loader and new one. ?This latest download appears to be missing some Kiel project support files. ?For example my old bootloader has the ¡°BL_SD.axf¡± file it uses but
By Brendan · #28535 ·
Re: Mount Disconnect and Ignores Safety Limit
Paul, I saw very similar symptoms with my mount 3 times over last month. 20 nights, give or take. I do imaging with KStars/Ekos. The mount is connected to PC via Ethernet, HC is not connected at all.