Meridian Flip issue is not resolved after upgrading GeminiTelescope Driver to 1.1.28 (as shown above). Tonight NINA connected to all devices, but was slow to connect to the G11 Mount (this is new, it used to connect fine). After a couple tries it connected. I setup my imaging sequence. I was able to Slew and Center on my object just fine and start the sequence.?
?
All ran well until it was time for the Meridian Flip. The Flip dialog opened in NINA, then No flip. The dialog Checked off the flip and went on to AutoFocus even though no flip occurred. I stopped the sequence. Tried to manually Slew and Center, nothing happens. And I get two errors.?
?
1: ASCOM GeminiTelescope server? ? Serial Port timed out.?
2: NINA: ASCOM Driver Error? ?SlewEquatorialAsync
?
Slew commands give the errors. But I can Park the scope from NINA with no issue. Weird. This setup worked fine for two years up until three nights ago when it stated failing Meridian flips.?
?
There are Log files for both GeminiTelescope, and ASCOM if needed for diagnostics.?
?
Could it be a bad USB cable ? I will swap that tomorrow.?