Hey Gary I finally got some time to take a look at my rig:
?
All tubes were pulled from my other TR-4CW rig and put into the TR-4CW/RIT rig because the tubes work and all tested strong on my calibrated tube tester.
?
Here are the results to the questions you have asked me.
?
10 Volts does go to the PTO
?
PTO puts out a strong signal on my spectrum analyzer when measured to where the signal wire goes to on the small board and tracks from 4.8-5.6 Mhz (100Khz lower and higher than what is printed on the PTO case but most likely correct)
?
PTO signal to ground measures 327.2 ohms
?
PTO signal on small board measures -27.2dB on my spectrum analyzer when directly coupled
?
V1 pin 2 reads same signal but at -61.7dB on my spectrum analyzer when directly coupled
?
Ohmed out where PTO signal goes to small board to pin 2 on V1 tube and I measure 104 ohms
?
QSL?
?