Re: T-4XC Meter Shunt Resistor?


 

Thanks Dan & Peter!
?
R49 came in at around 1600 ohms, replacing tomorrow. Surprisingly, Amazon has them but you have to buy in bulk. I just received the unusual message after my order,?
"Your order for 10PCS 1.5K Ohm Resistor from FOCMKEAS has been confirmed"
Can't wait to read the review comments with a vendor name like that.?
?
I'm replacing the 3.3 ohm with a precision 1% and I'm going to run leads from it to banana jacks that I'm installing in the extra holes next to the cinch jones connector.?
?
At 60mA bias I should read a drop of .198V across the jacks. With that funky non-zero meter in the T-4, I wonder what the actual bias is that I'm currently running.?
?
Hopefully the extra wire length won't create any parasitic hooligans.?
--
Craig/W8CS