¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io

Re: L7 question


 

OK sorry for the mistake I used the term in reference to the meter not reading correctly.

73 Tim
WB8UHZ

On Tuesday, January 7, 2025 at 10:55:56 PM EST, Jim Shorney via groups.io <jimnu0c@...> wrote:



OK but please stop calling them shunts. They are series voltage dropping resistors. The only shunt is the pot. A shunt is a resistance across the meter terminals to increase the current value needed for a full scale reading.


On Wed, 8 Jan 2025 03:38:34 +0000 (UTC)
"amfone via groups.io" <amfone20000@...> wrote:

>? Jim thanks for your help regarding the location and the voltage requirements of the shunts.


--

73

-Jim
NU0C





Join [email protected] to automatically receive all group messages.