On Tuesday, January 7, 2025 at 09:32:59 PM EST, Thomas W9TAB via groups.io <electron@...> wrote:
Your L7 S/N is close to mine, I would perform the grid current meter calibration step to verify the meter functionality which is supplied by a voltage divider network (1 ohm 12w resistor) into a 200ua meter movement.?
I used an adjustable current / voltage bench top power supply and my Fluke 87 DMM set to madc, I checked it with the Fluke and power supply first then I put the grid circuit in series, there is an adjustment on the metering board.?
My plate current meter has an external shunt on the back of the meter and can be checked in a similar way as the grid current setup + to test point ¡°A¡± (Orange wire near edge of board) and the return would be pin 6 on the rear connector for the
plate circuit.?