Both of the Parasitic Choke resistors were kind of burnt. That may be because of parasitics as C39 and 40 were the blown capacitors. I don't think the breakers blew as it seems when the caps went I lost HV. Haven't checked the PS to see if the .82 resistor blew, been cleaning up the area around the tubes.? All the RFC's look ok, no burn marks and check out with an ohm meter.? I have fully grounded grids as I did that not too long ago.? Resistance between grid and filaments check ok. Along with resistance between grid and plate. I really think some type of parasitic oscillation took place while on 15 meters.? I will carefully clean and replace those bad components and then bring it up gradually.
So much for trying to contact Easter Island as they were on strong last night at 221262.00. I could hear them very well about a 58 here and would have liked to have that contact.
73? Bob