We haven't experienced this issue, but I remembered that there is a setup item in the Analog Repeater menu which allows you to configure the ID Output.? I just checked the KE5RCS setup by running the computer at the repeater site and then using ID-RP3 to access the configuration of the repeater.
The Analog Repeater menu has an ID Output menu, and this must be set to ON.? Then you select CW output.? The Call Sign is entered in the Repeater Call Sign menu in the Common menu.? Did you do your setup this way?
On Wed, Nov 22, 2023 at 1:14?PM Ron N5ECG <n5ecg@...> wrote:
Just purchased an ID- RP4010V with the ID-RP3 software.? After performing initial setup and just getting it going in analog mode only, the repeater does not send any Morse ID's.? All other functions of the repeater seem to work.? I had ICOM check the setup and all looks proper. Has anyone else experienced this issue?? Need to resolve this to move forward. Ron, N5ECG