File /Doug Moore's Archives/Doug Moore meter puller.docx uploaded #file-notice
The following files and folders have been uploaded to the Files area of the [email protected] group. * /Doug Moore's Archives/Doug Moore meter puller.docx (
By Group Notification <noreply@...> · #823 ·
Re: ENI meter source
here is the Doug Moore meter puller document
By Michael J Emerson · #822 ·
Re: ENI meter source
Clint, Try using a heat gun or hair dryer on the glue around the base of the meter. I have disassembled ENI meters using heat. If you remove the board and leave the meter in the case you can use a
By Lenox Carruth · #821 ·
Re: ENI meter source
George, I tried the geotropism test by holding the assembled unit upside down, no change. ?Maybe if I open it I can repair it. ?What do you suggest, an X-Acto saw? Clint
By Clint · #820 ·
Re: ENI meter source
Peter, It's a little hard to see but it doesn't appear to be hitting the face. ?The needle arc is parallel to the face. Clint
By Clint · #819 ·
Re: ENI meter source
Michael, I tried your suggestions but it still hangs up in the same place. Clint
By Clint · #817 ·
Re: cdv700 probe
Thank you for the offer, David. ?I found a socket and got it repaired. ?Another good 700 back from the dead. Clint
By Clint · #816 ·
Re: ENI meter source
Good on the horseshoe. That's good news. Those are really rugged, sledom have a serious problem compared to the much smaller circular one (no gap).Also the plastic on the older horseshoe ones is
By Geo Dowell · #815 ·
Re: ENI meter source
I had an issue with an old Ludlum from 1976 where the magnet metal grains were falling out and caused a mechanical bridge between the magnet and needle coil. I am curious if you can run the black zero
By Stephen Nelson · #814 ·
Re: ENI meter source
just in case, have you looked athe clearance between the needle and the face of the scale? i've seen bubbled/lifted paint before. p
By peter · #813 ·
Re: ENI meter source
Clint - do you think it could be static charge on the meter face? I had a similar problem with an Eberline RM-15 meter and fixed it by using anti-static solution (DIY). You could also try a
By Michael J Emerson · #812 ·
Re: ENI meter source
I think it's a horseshoe.
By Clint · #811 ·
Re: ENI meter source
Clint, does that meter have a magnet that is round like a ci8rcle, not horseshoe shaped?If so, those are pressed ceramic not iron, and are notorious for shedding flakes of its material, which clogs up
By Geo Dowell · #810 ·
ENI meter source
Hello, I just got another shiny new, clean ENI 700 in mint condition and while the circuit seems to be working the meter stops around 200 CPM as if it is hitting something. ?I know the high-range
By Clint · #809 ·
Re: Newbie at this, how do you calibrate the CD V700?
By Geo Dowell · #807 ·
Re: Newbie at this, how do you calibrate the CD V700?
Happy Holidays George! Very interesting and illuminating! Pavlos
By Pavlos H · #806 ·
Re: Probe voltage and calibration.
Voltage does affect the response unless you are on the plateau. That response curve should be published somewhere or when you buy a tube. Stay within the plateau and you are fine. Less voltage is
By David71 · #805 ·
Re: Newbie at this, how do you calibrate the CD V700?
The 6993 tube is energy compensated for gamma, but counts are counts.
By David71 · #804 ·
Re: Probe voltage and calibration.
This is great, real world data Mike, thank you.
By Clint · #803 ·
Re: Probe voltage and calibration.
Clint, This gives me an excuse to play with my new (to me) Bicron frisk-tech scaler!? It has about a 300 mV threshold.? The source used was a Fiestaware bowl with the pickle probe clamped in a