All readers, I second what Perter said:
"Even if 900V is not present, it might be intermittent, so exercise caution. It might appear while probing if there is a cold solder joint or a cracked trace ?"


Geo


From: "peter via groups.io" <epkoncept@...>
To: "CDV700CLUB" <[email protected]>
Sent: Wednesday, April 27, 2022 4:43:34 PM
Subject: Re: [CDV700CLUB] Leni conversion #3

In the manual, the schematic pages usually show the nominal voltages. Perhaps, after the visual check you can probe the board for voltages.
If -15V is not there, that's a hint. osc tr, or transformer is dead ?

Even if 900V is not present, it might be intermittent, so exercise caution. It might appear while probing if there is a cold solder joint or a cracked trace ?

Do you have any liquid flux ? I find that the easiest way to fix cold solder joints is to reheat the joint after applying flux. If you don't have flux, just add a little solder to each joint as you touch them up.