Keyboard Shortcuts
Likes
Search
Re: Question and an interesting site for those that modify CDV700s and more.
Roger Whatley
¿ªÔÆÌåÓýWell, hmmm...... 1) I yield to your point, and, 2) I often find I do not understand
everything I "know." This appears to be another one of those
times........
btw, I totally agree with your
comment about? the metering circuit input cap. Essentially its
time constant with the input resistance is such that the
capacitor is discharging throughout the period of the "pulse."
That means that the fast fall on the leading edge does not get
quite to the full peak of the input pulse.? My recollection is
that it was about 90% in simulations..... and my recollection is
that there was a good reason for not making it larger.... I
forget what it was.
Can you perhaps do the same Vpp measurements on a 6993? I wanted to do that over two years ago but I did not have a HV scope probe. So I am looking again at the 6993
specs (enclosed)........? If I understand this correctly, the
"Pulse Amplitude when operating at 890V" is 2Vmin for the
6993/114 GM tube. That of course, does not mathematically
preclude a full 890VPP pulse amplitude at the GM tube but I
never found anything to suggest that either. Until now. In the second enclosed document, a
manufacturing test set up specified a 1Vmin pulse amplitude
requirement for the 6993 tube. It specified a 50pF coupling cap,
I suppose to a 1Meg scope input? I haven't read the document in
over 2 years.... So I still think I do not understand everything I "know." rogerw
On 4/3/2022 5:22 PM, Geo Dowell wrote:
On Sun, Apr 3, 2022 at 01:40 PM, Roger Whatley wrote: -- rogerw On the Catclaw ¦¬¦¯¦«¦¸¦ ¦«¦¡¦¢¦¥ The PanDemic is over, but the DemPanic goes on. MisDisMal is a dictator's tool of repression. lionel-101 &103 tube datasheet.pdf
lionel-101 &103 tube datasheet.pdf
6993 specification sheet.pdf
6993 specification sheet.pdf
|