Cyanoacrylate (superglue) would allow a quick repair and the toroid parts would be closer together due to a thinner layer compared to the usual two-tube adhesive.
On Thu, Apr 5, 2018 at 11:00 AM, Mvs Sarma <mvssarma@...> wrote:
However, a broken toroid after having calibrated a coil, If glue repaird, would change its value. Perhaps the inductor value woudl reduce silghtly.? After the suggested gluing, I would recommend to peak the filter for performance.
Regards MVS Sarma ?
On Thu, Apr 5, 2018 at 2:25 PM, Gordon Gibby <ggibby@...> wrote:
A bit of 5 min epoxy to hold them together tightly is all I would do. ?
Just bits of metal suspended in ceramic/resin.?
On Apr 5, 2018, at 04:22, chris gress <Chrisg0wfh@...> wrote:
The cores for L1/L2 are T30-6 the copper wire is 40 turns I am not show of the wire swg the cores are yellow I believe you should be able to pick up new cores easily got mine off eBay cheep chris?
I recently received a BiTX40 (thanks to the people who helped me with finding the manual).? While going through the various topics here, I was taking a closer look at the board and noticed L2 and L3 are cracked.? I noticed someone had answered another question
about parts and suggested,??but
I do not know enough of the part, besides it being 6uH based on the schematic, to be able to order a replacement.? Would someone be kind enough to let me know the part number and the specs for the part for my education.