Re: Alpha and Beta particle Spec


 

I saw a lot of options in the menus!?


On Sat, May 28, 2022, 7:41 PM Dude <dfemer@...> wrote:

Call any time 702-521-8577.

Dud

?

?

From: [email protected] [mailto:[email protected]] On Behalf Of Geo Dowell
Sent: Saturday, May 28, 2022 5:33 PM
To: [email protected]
Subject: Re: Alpha and Beta particle nuclear decay studies. Alpha and Beta particle Spec

?

?

Dud, when the Memorial Day holiday is over I hope to get you on the phone to walk me through the command change step to get the e-17 thing resolved, you know programming is not my thing!

?

Geo

?

?

----- Original Message -----
From: Dude <dfemer@...>
To: [email protected]
Sent: Sat, 28 May 2022 18:47:55 -0400 (EDT)
Subject: Re: Alpha and Beta particle nuclear decay studies. Alpha and Beta particle Spec

?


margin: 0.0in;
font-size: 12.0pt;
font-family: "Times New Roman" , serif;
}
a:link, span.MsoHyperlink {
color: blue;
text-decoration: underline;
}
a:visited, span.MsoHyperlinkFollowed {
color: purple;
text-decoration: underline;
}
p {
margin-right: 0.0in;
margin-left: 0.0in;
font-size: 12.0pt;
font-family: "Times New Roman" , serif;
}
p.MsoNoSpacing, li.MsoNoSpacing, div.MsoNoSpacing {
margin: 0.0in;
font-size: 16.0pt;
font-family: Arial , sans-serif;
color: black;
}
span.EmailStyle19 {
font-family: Arial , sans-serif;
color: black;
top: 0.0pt;
letter-spacing: 0.0pt;
font-weight: normal;
font-style: normal;
}
*.MsoChpDefault {
font-size: 10.0pt;
}
div.Section1 {
page: Section1;
}
/*]]>*/

Yup

?

?

From:
[email protected] [mailto:[email protected]] On Behalf Of Geo Dowell
Sent: Saturday, May 28, 2022 2:55
PM
To: [email protected]
Subject: Re: Alpha and Beta
particle nuclear decay studies. Alpha and Beta particle Spec

?

By the way, doesn't the
red MUTE light coming on tell you it's in alarm mode already?

?

Geo

?

?

----- Original Message
-----

From: Nick Andrews <nickjandrews@...>

To: [email protected]

Sent: Sat, 28 May 2022 16:56:26 -0400 (EDT)

Subject: Re: Alpha and Beta particle nuclear decay studies. Alpha and Beta
particle Spec

?

I'm thinking I don't need
the possible fragile LED stack on top,? so a possibility for me is to
either just disconnect it and cap the hole or even install red and green LEDs
in the front cover like Geo's mod on the LENi conversions.?

?

It looks like the little
Gast pump might've been left in NM after all.? ?I have a Thomas
compressor,? like an airbrush type, that seems to output a goodly amount
of air.? I could set it in a plastic tote with the source and have it push
air into the SmartCAM,? or rig up a different box with the source in it
hooked to the monitor with a hose to pull air through it rather than
push.? But I think pushing air through would be better so it could cool
itself more effectively.?

?

On Sat, May 28, 2022, 4:40
AM Geo Dowell <GEOelectronics@...>
wrote:

I simply unplugged the
Sonalert! Also the LED stack.

?

Geo

?

----- Original Message
-----

From: Nick Andrews <nickjandrews@...>

To: [email protected]

Sent: Sat, 28 May 2022 02:12:19 -0400 (EDT)

Subject: Re: Alpha and Beta particle nuclear decay studies. Alpha and Beta
particle Spec

?

I bet just a piece of tape
over it will go a long way.? Maybe a piece of thin cardboard.?
?I was lightly holding a thumb on it and that killed most of the
noise.?

?

I need to pull that little
Gast I have off the trailer,? see of it works,? then if it will pull
enough volume...

?

On Sat, May 28, 2022, 1:08
AM Dude <dfemer@...>
wrote:

Nick,

The Gast pump is back up

after cooling down so now I put a fan on it. I¡¯ve used the Clear Latch
Conditions

often enough to mute it, but it¡¯s very ?loud getting close to it to open
the

Monitor tab.

?It actually works better

now and I had to use the valve to keep the flow below the Hi alarm

Dud.

?

From:[email protected]
[mailto:[email protected]]
On Behalf Of Nick Andrews
Sent: Friday, May 27, 2022 10:30

PM
To:[email protected]
Subject: Re: Alpha and Beta

particle nuclear decay studies. Alpha and Beta particle Spec

?

Run a fan across the pump...

?

If you turn the security key,? you can Mute the alarm with
the

lower right button on screen.?

?

On Fri, May 27, 2022, 5:11 PM Dude <dfemer@...>

wrote:

Well, after 6+ hrs of running and taking 20 min data between the

RAD7 and the ?Impex CAM, the GAST pump died (yes it was hot and was maxed

out at 32L/m). I can attest to the fact the CAM LOW FAIL alarm is LOUD and hard

to mute without getting into the command mode which requires getting even

closer to the Sonalert. We¡¯re going to need a bigger pump ?What do they

recommend I wonder, my guess is a HiVol.

I think I¡¯ll go have a Dixie cup full of a fine Boxed Merlot and

grieve on the last Gasp of my poor $20 Gast pump.

Dud

?

From: dfemer [mailto:dfemer@...]

Sent: Friday, May 27, 2022 1:59 PM
To: '[email protected]'
Subject: RE: Alpha and Beta
particle

nuclear decay studies. need some pointers to background info on this topic

?

Everything is supposedly in the manual, however we live by our

wits alone.

Dud

?

From:[email protected]

[mailto:[email protected]]
On Behalf Of Geo Dowell
Sent: Friday, May 27, 2022 1:46 PM
To:[email protected]
Subject: Re: Alpha and Beta

particle nuclear decay studies. need some pointers to background info on this

topic

?

THANKS Dud, great to know. Once I get it lined out, I'll start

comparing to the Femtotech.

?

how on earth did you figure that, was it in the manual?

?

Geo

?

----- Original Message -----


From: Dude <dfemer@...>


To: [email protected]


Sent: Fri, 27 May 2022 14:36:57 -0400 (EDT)


Subject: Re: Alpha and Beta particle nuclear decay studies. need some pointers

to background info on this topic

?




margin: 0.0in;


font-size: 12.0pt;


font-family: "Times New Roman" , serif;


}


a:link, span.MsoHyperlink {


color: blue;


text-decoration: underline;


}


a:visited, span.MsoHyperlinkFollowed {


color: purple;


text-decoration: underline;


}


p {


margin-right: 0.0in;


margin-left: 0.0in;


font-size: 12.0pt;


font-family: "Times New Roman" , serif;


}


p.MsoNoSpacing, li.MsoNoSpacing, div.MsoNoSpacing {


margin: 0.0in;


font-size: 16.0pt;


font-family: Arial , sans-serif;


color: black;


}


span.EmailStyle19 {


font-family: Arial , sans-serif;


color: black;


top: 0.0pt;


letter-spacing: 0.0pt;


font-weight: normal;


font-style: normal;


}


*.MsoChpDefault {


font-size: 10.0pt;


}


div.Section1 {


page: Section1;


}


/*]]>*/

Geo/Nick

To convert the wacko ?E-17


radon reading go to command mode with the Key get to the Radon tab and change


the 1e-16 to 186 which is the Po218 half life.. Bring up the Radon Acute

default


page to read Po 218 acute and Radon Acute. It will be in pCi/ml multiply by


1000 to get pCi/l.? I need to use Radon raw and Po raw but I still need to

figure


out how to do that.

I¡¯m running the RAD 7and


the SmartCAM together and the CAM showing 3.5 pCi/l ?while The RAD 7 is

averaging


4.0 pCi/l ?+- 2.1. Doing a manual calculation it always comes up low by a


factor 3 or so. That ma be due to not having all their corrections in there and


using acute cps

Dud

?

From:
[email protected]

[mailto:[email protected]]
On Behalf Of Geo Dowell
Sent: Friday, May 27, 2022 10:42


AM
To:
[email protected]
Subject: Re: Alpha and Beta


particle nuclear decay studies. need some pointers to background info on this


topic

?

"

Geo,

What kind of solid samples


are going to run? One needs to be very careful not to crap up the detector.


Most alpha samples are via liquid chem electro-deposited on steel disk, swipe


and air sample filters. Don¡¯t put a loose sample in there.

Dud"

?

A few different


electroplated discs on the IMPEX,

?

But other units, anything


I can lay my hands on

?

Been collecting and


waiting for this phase for a long time. All new to me.?

?

Geo

?

----- Original Message


-----



From: Dude <dfemer@...>



To: [email protected]



Sent: Fri, 27 May 2022 13:16:02 -0400 (EDT)



Subject: Re: Alpha and Beta particle nuclear decay studies. need some pointers


to background info on this topic

?





margin: 0.0in;



font-size: 12.0pt;



font-family: "Times New Roman" , serif;



}



a:link, span.MsoHyperlink {



color: blue;



text-decoration: underline;



}



a:visited, span.MsoHyperlinkFollowed {



color: purple;



text-decoration: underline;



}



p {



margin-right: 0.0in;



margin-left: 0.0in;



font-size: 12.0pt;



font-family: "Times New Roman" , serif;



}



p.MsoNoSpacing, li.MsoNoSpacing, div.MsoNoSpacing {



margin: 0.0in;



font-size: 16.0pt;



font-family: Arial , sans-serif;



color: black;



}



span.EmailStyle19 {



font-family: Arial , sans-serif;



color: black;



top: 0.0pt;



letter-spacing: 0.0pt;



font-weight: normal;



font-style: normal;



}



*.MsoChpDefault {



font-size: 10.0pt;



}



div.Section1 {



page: Section1;



}



/*]]>*/

Peter,

The Smart Cam and usual



Radon sampling run around 32 L/min (1 cft/min).

Geo,

What kind of solid samples



are going to run? One needs to be very careful not to crap up the detector.



Most alpha samples are via liquid chem electro-deposited on steel disk, swipe



and air sample filters. Don¡¯t put a loose sample in there.

Dud

?

From:

[email protected]

[mailto:[email protected]]
On Behalf Of Geo Dowell
Sent: Friday, May 27, 2022 1:45 AM
To:

[email protected]
Subject: Re: Alpha and Beta



particle nuclear decay studies. need some pointers to background info on this



topic

?

P, are you interested in



Alpha in air? That's fine, my intention was to do Alpha solid samples with my



6A head.

?

Geo

?

?

?

----- Original Message



-----




From: peter via

<epkoncept=[email protected]>




To: [email protected]




Sent: Thu, 26 May 2022 23:54:53 -0400 (EDT)




Subject: Re: Alpha and Beta particle nuclear decay studies. need some pointers



to background info on this topic

?

Need some advice.




What sort of airflow does the Eberline 6A expect ?




Or more useful is what sort of airflow should I use ? I don't know how make use



of the airflow control circuit in the 6A so I thought I might plumb the air



directly from a pump.




I have an old SKC air sampler pump. It sucks, but I can also get it to pump. It



goes up to 5l/min




4l/m @ 20" of back pressure.






P

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?