Re: Issues with TinySA USB Connection in C#
On Thu, Jan 9, 2025 at 09:00 PM, hwalker wrote:
Well, this is definitely an error that appeared after
*tinySA4_v1.3-435-g391dca6*
HW Version: 167.
I started the Python script I provided yesterday,
By
voloshyn.v.v@...
·
#19038
·
|
Re: Issues with TinySA USB Connection in C#
I did some testing over the past day and suspect that in the tight loop that you are running, without doing anything with the amplitude or frequency data, the console 'frequency' and 'data' commands
By
hwalker
·
#19037
·
|
Re: Issues with TinySA USB Connection in C#
Many, many thanks
This is exactly when a change was made to a part of the code that uses multiple threads.
I will need some time investigate this.
--
Designer of the tinySA
For more info go to
By
Erik Kaashoek
·
#19036
·
|
Re: Issues with TinySA USB Connection in C#
I think i foound version when this error appeared.
I see exception on this version and newer.
tinySA4_v1.3-438-gd7f97cd
HW Version:167
2025-01-09 14:26:29: 843: (-50.75, 30159987.0)
An error
By
voloshyn.v.v@...
·
#19035
·
|
Re: 5.8GHz wideband video signal measurements
It seems that the problem that was causing the 404 error, reported by me and other users, is fixed. I can now access the page for all products, tinySA Ultra+ and the various additional external LNAs
By
@glradio
·
#19034
·
|
Re: ZS-407 is here
It seems that the problem that was causing the 404 error, reported by me and other users, is fixed. I can now access the page for all products, tinySA Ultra+ and the various additional external LNAs
By
@glradio
·
#19033
·
|
Re: measure>harmonics, some remarks
Correct. There are very low level internally generated spurs at 60 MHz and it's harmonics.
This is according the spec.
--
Designer of the tinySA
For more info go to https://tinysa.org/wiki
By
Erik Kaashoek
·
#19032
·
|
Re: New FW release: Improved correction curves for ZS406
All ultra devices use one common FW
Inside the FW it is detected which hw is present and the differences are covered by this single sw.
So there is no special zs406 version but a FW release may
By
Erik Kaashoek
·
#19031
·
|
Re: New FW release: Improved correction curves for ZS406
Good question...
Roger
By
Roger Need
·
#19030
·
|
Re: New FW release: Improved correction curves for ZS406
It shows which version is which in the WiKi.
All you have to do is read it.
By
Clyde Lambert
·
#19029
·
|
Re: New FW release: Improved correction curves for ZS406
QSL
Thank you Erik! ?Your continued efforts are much appreciated!
By
Dan Heather
·
#19028
·
|
Re: New FW release: Improved correction curves for ZS406
If you device has "Ultra" at the front it's a ZS405
If it has "Ultra+" you have either a ZS406 or ZS407 and the label at the back specifies which of the two
--
Designer of the tinySA
For more info go
By
Erik Kaashoek
·
#19027
·
|
Re: New FW release: Improved correction curves for ZS406
I have a TinySA that has unknown type number.? I bought it used from eBay and do not know its age.
There is no such number on the label on the backside of my unit.? The only appearance of "ZeenKo"
By
Dan Heather
·
#19026
·
|
Re: New FW release: Improved correction curves for ZS406
Also with latest FW
CONFIG/VERSION
--
Designer of the tinySA
For more info go to https://tinysa.org/wiki
By
Erik Kaashoek
·
#19025
·
|
Re: New FW release: Improved correction curves for ZS406
It says so on the back beneath the name Zeenko.
By
pa3cqn
·
#19024
·
|
Re: New FW release: Improved correction curves for ZS406
Erik,
How can I determine if my tinySA Ultra is a ZS406?
Thanks,
Mike N2MS
By
Mike N2MS
·
#19023
·
|
Re: New FW release: Improved correction curves for ZS406
Hi Erik - thanks for all the hard work, much appreciated. Do these new FW upgrades that are specifically identified as being for the new ZSXXX series of analyzers also apply to the original Ultra
By
Dino Papas
·
#19022
·
|
measure>harmonics, some remarks
So measuring harmonics uses the multiband feature and span sets the measuring span around the fixed harmonics calculated from the center frequency.
But after setting measure 'off' multiband is still
By
pa3cqn
·
#19021
·
|
New FW release: Improved correction curves for ZS406
New FW release
Version V1.4193
tinySA Ultra ZS406
Changes:
- Improved level correction curves for the ZS406
--
Designer of the tinySA
For more info go to https://tinysa.org/wiki
By
Erik Kaashoek
·
#19020
·
|
Re: What to do when a selftest fails
Hi.
I replaced U22 with an AS179-92LF that I received from Digikey yesterday.
My TinySA Ultra is now capable of calibration and passes all self-tests.
I would like to thank Erik and everyone who gave
By
Takuo Watanabe
·
#19019
·
|