Re: Test results
2nd update:
Answer Mode
------------------------------------------------------------------------
This parameter allows you to set the mode of answering the private call.
Option
By
DB9CR
·
#75
·
|
Re: Test results
Update:
Two radios with different DMR IDs connectd to same dmrtc can do private calls.
Private call from radio on dmrtc to brandmeister tier ii doesn't work. Trunking-Radio looks like call
By
DB9CR
·
#74
·
|
Re: dmrtc headless mode
Hello Adrian,
Thanks for updating the docs.
I can confirm that -h works - stupid error on my side.
My trunk mode repeater is running for evereral days now and only once needed a restart for unknown
By
DB9CR
·
#73
·
|
Re: dmrtc headless mode
Hello Christian,
I've fixed all documentation bugs now hopefully, and also added a
troubleshooting guide based on our conversation.
Can you confirm that your below issue with headless mode does not
By
Adrian M
·
#72
·
|
Re: dmrtc headless mode
Hello Christian,
I don't see anywhere the "-h" option when you start it headless.
You can omit the DISPLAY variable when using "-h".
Adrian
By
Adrian M
·
#71
·
|
Re: DMR Trunking: Hytera PD755 Stuck in "Out of Range"
Hello Adrian,
that explains it. Thanks!
73 Christian DB9CR
Am 01.07.2024 um 10:04 schrieb Adrian M:
By
DB9CR
·
#70
·
|
dmrtc headless mode
Hello Adrian,
while dmrtc has a headless mode, it seems that still, a connection to an X11 server is needed to start:
db9cr@tmo:~/software$ ( cd dmrtc/build ; DISPLAY= ./dmrtc )
qt.qpa.xcb: could
By
DB9CR
·
#69
·
|
Re: DMR Trunking: Hytera PD755 Stuck in "Out of Range"
I'm glad it finally works ok for you. I will fix the documentation bugs and add
some new sections based on this email thread as soon as possible.
Regarding the routing to DMRGateway:
Incoming calls
By
Adrian M
·
#68
·
|
Re: DMR Trunking: Hytera PD755 Stuck in "Out of Range"
Hello Adrian,
I changed:
DMRDelay to 0 <---- this needs fixing in the documentation!
burst_delay_msec? to 60
Control Channel back to channel zero.
Registration now works reliably. Also,
By
DB9CR
·
#67
·
|
Re: DMR Trunking: Hytera PD755 Stuck in "Out of Range"
Hi again Christian,
I suspect your issues with channel access might be related to the DMRDelay
setting. I'm not able to confirm right now, but I just checked the docs and it
seems they (wrongly)
By
Adrian M
·
#66
·
|
DMR Trunking: Hytera PD755 Stuck in "Out of Range"
Hello Adrian,
my setup is still not working, but after a lot of testing, I have some insights - maybe that rings a bell?
- Sometimes, the Hytera radio is able to book into the dmrtc, but most of the
By
DB9CR
·
#65
·
|
Re: DMR Trunking: Hytera PD755 Stuck in "Out of Range"
Oh I see, if there are no dropped packets everything is ok on this side.
Most likely not an interruption, but the receiver used for dsd-fme is
momentarily overloaded by the nearby high-power
By
Adrian M
·
#64
·
|
Re: DMR Trunking: Hytera PD755 Stuck in "Out of Range"
Hello Adrian,
did some more debugging.
CPU resources are not a problem.
$ cat /proc/cpuinfo
processor?????? : 0
vendor_id?????? : GenuineIntel
cpu family????? :
By
DB9CR
·
#63
·
|
Re: DMR Trunking: Hytera PD755 Stuck in "Out of Range"
Error 14 is due to the serial communication protocol between MMDVMHost and
MMDVM being slightly changed for trunking support. So the mmdvm_sdr branch is
not compatible with the trunking branch.
By
Adrian M
·
#62
·
|
Re: DMR Trunking: Hytera PD755 Stuck in "Out of Range"
The "trunking" branch should be used in both MMDVM-SDR and MMDVMHost-SDR.
I am not sure about the cause of the interruptions.
One thing to check for is that qradiolink is at the latest (0.8.13-2 or
By
Adrian M
·
#61
·
|
Re: DMR Trunking: Hytera PD755 Stuck in "Out of Range"
Hello Adrian,
as said -? in the MMDVM section in your documentation, "git checkout mmdvm_sdr" gives me the error 14. "git checkout trunking" resolves error 14, but produces the interruptions in the
By
DB9CR
·
#60
·
|
Re: DMR Trunking: Hytera PD755 Stuck in "Out of Range"
Unfortunately, the solution was not permanent.
The signal on the control channel ist again interrupted 1-2 times per second.
In dsd-fme, messages are coming in blocks like this, with a short break
By
DB9CR
·
#59
·
|
Re: DMR Trunking: Hytera PD755 Stuck in "Out of Range"
Hello Christian,
You are completely correct, that is how it works.
Regarding your errors, I see that you have solved them, congratulations!
The full documentation is now at this
By
Adrian M
·
#58
·
|
Re: DMR Trunking: Hytera PD755 Stuck in "Out of Range"
rm -rf MMDVM-SDR/
git clone https://codeberg.org/qradiolink/MMDVM-SDR
cd MMDVM-SDR
git checkout mmdvm_sdr
mkdir build && cd build
cmake ..
make -j 2
[...]
Runnign with this MMDVM binary, MMDVMHost
By
DB9CR
·
#57
·
|
Re: DMR Trunking: Hytera PD755 Stuck in "Out of Range"
Hello Adrian,
things start to make sense. Lookong at the output of MMDVMHost, I see an error something like "message 14". 14 is the ID of Aloha. I made a clean recompile of MMDVM-SDR and now I get
By
DB9CR
·
#56
·
|