Keyboard Shortcuts
ctrl + shift + ? :
Show all keyboard shortcuts
ctrl + g :
Navigate to a group
ctrl + shift + f :
Find
ctrl + / :
Quick actions
esc to dismiss
Likes
Search
Voltage sensing diode
I have two Nanos and neither had the diode. I added the diode shown on the schematic an SD103AWS SMD part and then the battery indicator will work fine. Note it interferes with the battery connector on the board so I had to slice an angle off the bottom side of shell so it would fit back on the board.
I wonder of they left off that inexpensive diode because it interfered with that battery shell? |
KV5R
I didn't have an SMT diode so just used an axial 1N4148. Can be done if one forms the leads with fine-point tweezers. It works fine.
Also, used the clipped lead wires to make little hooks for mini-grabbers on VDD and BOOT0, though with the latest firmware jumpering is no longer necessary for firmware loading.. 73, --kv5r |
You can test this firmware. This is improved version of edy555 firmware v 0.3.0. It shows battery indicator even if diode is not installed.
Also it shows battery voltage on CONFIG => VERSION screen. Note that firmware assumes that diode voltage drop is 500 mV, so it adds 500 mV for correction. PS: this version has si5351 hardware check, so if you see the red PLL indicator under the battery it means that you have defective si5351 chip. Defective si5351 may works unstable above 200 MHz. In addition, this firmware has bug fixes, better noise floor and more precise measurement. I recommend you to cleanup settings and perform calibration after upgrade. You can perform setting and calibration cleanup with the following console command: clearconfig 1234 |
Do you have the 0.3.1 fix from edy555 in as well?
toggle quoted message
Show quoted text
-- Rune / 5Q5R On Mon, 21 Oct 2019 at 21:42, QRP RX <qrp.ddc@...> wrote:
On Mon, Oct 21, 2019 at 10:38 PM, Dean Smith wrote:The firmware that I mention above supports 10 kHz - 1500 MHz range. The |
You selected the wrong converter - just like I did.
toggle quoted message
Show quoted text
Select I want to generate a DFU.Then, click on the S19 or hex button - not the bin. That should do it. On Monday, October 21, 2019, 4:20:51 p.m. GMT-4, Dean Smith <bardezbiker@...> wrote:
ok just downloaded 0.3.1 build. I generated with the dfu file manager, the ch.bin from the build but all i get is a 301 byte file. it processes it too quickly, so i dont think it's successful. Hmm... |
Yes, firmware 0.3.0m already has fix from version 0.3.1 from @edy555. :)
Actually the bug which is fixed by @edy555 in 0.3.1 was missing from 0.3.0m. It was already fixed. The same other bugs which currently present in 0.3.1 from @edy555 already fixed in 0.3.0m. 0.3.0m missing sine table removement from 0.3.1, but it won't affect functionality. |
so, this firmware /g/nanovna-users/message/5445 has more bug fixes and improvements in comparison with 0.3.1 :)
|
to navigate to use esc to dismiss