¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io

Consistent error msg in Linux


 

Traceback (most recent call last):
File "NanoVNASaver/Charts/Polar.py", line 45, in paintEvent
File "NanoVNASaver/Charts/Polar.py", line 87, in drawValues
OverflowError: argument 2 overflowed: value must be in the range -2147483648 to 2147483647

More info as needed/requested

Just getting started here but this bit of frustration may be familiar to someone :-)


 

OverflowError: argument 2 overflowed: value must be in the range -2147483648 to 2147483647
My >>guess<< (since you did not mention a device, firmware level, measurement being made)
is that the nanoVNA had no DEVICE calibration. Consequently, "impossible" values may be returned.
In other cases, corrupted USB data (e.g. bad cable or EMI) may be to blame.


 

Nanovna-saver binary V 0.3.4 "Interpol Bug Hunting Edition"
OS: Linux 3.16.0-4-amd64/x86_64 - Distro: Debian 8.7 - CPU: 4 x Intel Xeon (3000.000 MHz) - Processes: 197 - Uptime: 225d 9h 43m - Users: 3 - Load Average: 1.36 - Memory Usage: 4929.43MB/24164.88MB (20.40%) - Disk Usage: 202.91GB/266.25GB (76.21%)

Copyright (C) 2019, 2020 Rune B. Broberg
Copyright (C) 2020 NanoVNA-Saver Authors

This program comes with ABSOLUTELY NO WARRANTY
This program is licensed under the GNU General Public License version 3

See for further details.

Settings: /home/kop/.config/NanoVNASaver/NanoVNASaver.ini
Traceback (most recent call last):
File "NanoVNASaver/Charts/Polar.py", line 45, in paintEvent
File "NanoVNASaver/Charts/Polar.py", line 87, in drawValues
OverflowError: argument 2 overflowed: value must be in the range -2147483648 to 2147483647
Aborted (core dumped)
Annoying as I can "almost" get it to work :-(


 

Oristo
DEVICE calibration performed alternately at device and through Nanovna-saver as per instructions.
Measuring reflected plot
Version: v0.2.3-2-g8ac9166 Oct 18 2019 - 16:10:56


 

I have seen crazy readings if the device has not been used for a long time and the battery is discharged.

Gary AG7TH

On 7/8/20 06:32, AF7XT wrote:
Oristo
DEVICE calibration performed alternately at device and through Nanovna-saver as per instructions.
Measuring reflected plot
Version: v0.2.3-2-g8ac9166 Oct 18 2019 - 16:10:56


 

Traceback (most recent call last):
File "NanoVNASaver/Charts/Polar.py", line 45, in paintEvent
File "NanoVNASaver/Charts/Polar.py", line 87, in drawValues
OverflowError: argument 2 overflowed: value must be in the range -2147483648 to 2147483647
Aborted (core dumped)

Still..............


 

Hi AF7XT,
Please try 0.3.6 - possible version error, although I couldn't start only 0.3.6 on a 32-bit system.
73, Gyula HA3HZ
--
*** If you are not part of the solution, then you are the problem. ( ) ***